Unit Description; Electrical Diagram Of The System - Ingeteam INGECON SUN STORAGE 1Play TL M Manual De Instalacion Y Uso

Ocultar thumbs Ver también para INGECON SUN STORAGE 1Play TL M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ingeteam

2. Unit description

The INGECON SUN STORAGE1Play TL M hybrid inverter allows combining photovoltaic generation with energy
storage without additional photovoltaic inverters.
This inverter has a double monitoring system for the maximum power point (MPPT), allowing to extract the
maximum power from the PV array, even in installations on roofs with different directions or partial shade.
Thanks to the Energy Management System (EMS) included, the installation can be monitored at all times via PC or
cell phone with the free INGECON SUN Monitor application.
In addition, it is capable of working in off-grid mode or connected to the grid in the following types of installation.
Stand-alone installations
System disconnected from the distribution grid that provides AC power to a set of consumers.
This type of installation allows installing an auxiliary generator, which can be started up through a voltage-free
output to charge the batteries.
UPS installations
System connected to the distribution grid that is used as back-up in the event of a power cut. In this case the
installation works as an Off-line type UPS.
Self consumption installations
System connected to the distribution grid that seeks to minimize grid consumption and increase self-supply.
If energy production is greater than demand, the excess can be used to charge the batteries and to inject into
the grid. It also includes the Battery-Backup function, which allows the inverter to power critical loads from the
batteries and photovoltaic panels in the event of a power cut.
INFO
For more information about this type of installation, see the "Technical guide for installations with
INGECON SUN STORAGE 1Play TL M" available on the Ingeteam website.

2.1. Electrical diagram of the system

Grid
Monitoring and start-up
12
Non-critical loads
Wattmeter
Batteries
INGECON SUN STORAGE
1Play TL M
Critical loads
PV 2
PV 1
ABH2014IQM01_A- Installation and Operation Manual
Unit description
AC
DC
RS-485
CAN Bus 2.0

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido