Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5. Mount O-ring by pulling it over the lid and tighten lid cover until you feel friction from the O-ring on both sides. Wind lid
further by one quarter of a turn to seal on the O-ring.
6. Reinstate and tighten lid lock screw.
7. Ensure that moisture does not penetrate to inside of electronics housing by creating a drip loop (bend cables downward)
immediately before cable glands.

Local display

Full graphical display
LED (for indication of key operation)
Capitance proximity keypad
Note
Local display timeout
If no key is pressed for 10 minutes, the display switches to show operation view.
Note
Operation does not require opening of the device. This means that the high degree of protection of IP67 and safety in
hazardous locations are guaranteed at all times.
12
FCT030 transmitter
A5E03650800-AH, 05/2015

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido