Technical Specifications - Ingersoll Rand N2G17FP Manual De Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 4.1 General
Delivery pressure
Maximum delivery pressure
Compressed air
Maximum feed pressure [psig]
Minimum feed pressure [psig]
Compressed air temperature range
Residual oil content
Pressure dew point
Ambient conditions
Temperature
Noise level
Dimensions and connections (Generator Only)
Dimensions (H x W x D) [in]
Net weight [lb.]
Connections
inlet
outlet
Output
Capacity at nominal conditions [scfm]*
Pressure Switch Settings [psi]
Purity at specified capacity [% by volume]
*Nominal conditions: feed pressure at inlet 145 psig, ambient temperature 68°F, ambient pressure 14.7 psi
Receiver Tank (Included on "FP" models)
Capacity
Weight [lb.]
Dimensions (H x OD) [in]
Outlet
Table 4.2 Maintenance kits
Part
Maintenance kit for N2G17
Maintenance kit for N2G70, N2G140
Oxygen Analyzer
Form 04581138-Edition 1

4. TECHNICAL SPECIFICATIONS

N2G17
9
Inlet pressure minus 14.7psi
190
110
40 to 100 °F
< 0,01 mg/m
< 40 °F
40 to 100°F
Less than 45 dB(A)
32 x 19 x 5
67
¼" NPT
¼" NPT
N2G17
3.5
130-145
60 gallon
150
51 x 25
½" NPT
N2G70, N2G140
190
145
3
33 x 22 x 6
77
½" NPT
¼" NPT
N2G70
8.0
N2G140
12.0
N2G180
17.7
95
80 gallon
230
50 x 32
½" NPT
Part No.
637407
637408
637409

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

N2g70fpN2g140fpN2g17N2g70N2g140

Tabla de contenido