5-4-7 SYNC
(1) By L or R button, INT, LL, EXT VS or EXT VBS can be selected.
(2) INT = Internal Lock
This is for internal sync lock mode, controlled by internal crystal oscillator.
(3) LL = Line Lock
This is for AC line lock mode. In this AC
Line Lock mode, phase adjustment can
be possible. To do it, Press E button,
and the screen at right shows up for
coarse and fine phase adjustment.
① COARSE
It makes possible to have 90 degree
increment from 0°, 90°, 180° or 270°.
② FINE :
By L or R button, fine adjustment of the phase is possible.
(4) EXT VS
By pushing E button, the screen for
adjustment will appear and the H phase
adjustment can be done by L or R
button.
Note that this mode can be valid when
VS signal input with Gen-lock mode.
(5) EXT VBS
By pushing E button, the screen for
adjustment will appear and the following
parameters are becomes controllable.
① H.PHASE
The horizontal phase can be
controlled by L or R button.
② SC COARSE
The sub-carrier phase can be
controlled by L or R button with 90
degrees steps.
③ SC FINE
After the above SC COASE adjustment, fine tuning of sub-carrier phase
can be controllable by L or R button.
        SYNC  LL
  COARSE       0 DEG
  FINE      L・・・・I・・・H
      RET   EXIT
        SYNC  VS
  H PHASE   L・・・・I・・・H
      RET   EXIT
        SYNC  VBS
  H PHASE   L・・・・I・・・H
  SC COARSE    0 DEG
  SC FINE   L・・・・I・・・H
      RET   EXIT
E-19