2. 1. 4. Installing the drive/tube assembly
,QVWDOO DQG ¿[ WKH GULYHWXEH DVVHPEO\ RQWR WKH HQG
1)
bracket (f) and onto the drive bracket (g) :
1
(QVXUH WKDW WKH GULYHWXEH DVVHPEO\ LV VHFXUHG RQWR
the end bracket. This operation prevents the drive/
tube assembly from coming out of the end bracket
mounting.
'HSHQGLQJ RQ WKH W\SH RI EUDFNHW ¿W WKH VWRS ULQJ h)
2)
in place.

2. 2. WIRING

Cables which pass through a metal wall must be
protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving
parts.
If the motor is used outdoors and if the power supply
cable is of the H05-VVF type, then run the cable in a
UV-resistant conduit, e.g. trunking.
The cable for the LS 40 cannot be removed. If it is
damaged, return the drive to the After-Sales
department.
1
Leave the drive power supply cable accessible: it
must be possible to replace it easily.
1
Always make a loop in the power supply cable to
prevent water entering the drive!
Switch off the power supply.
-
Connect the drive according to the information in the
-
table below:
Neutral (N) Live (L1)
230 V
50 Hz
120 V
60 Hz
White

2. 3. COMMISSIONING

2. 3. 1. Checking the direction of rotation

Switch the power back on.
1)
Press the
button on the control point:
2)
If the motorised product rises (a), the direction of
a)
rotation is correct: Move onto the section entitled
"Setting the end limits".
If the motorised product lowers (b), the direction of
b)
rotation is incorrect: Move onto the next step.
Switch off the power supply.
3)
Reverse the 2 phase wires on the control point.
4)
Switch the power back on.
5)
Press the
button.
6)
Copyright © 2007-2014 Somfy SAS. All rights reserved.
Cable
Live (L2)
Blue
Brown
Black
(DUWK ( )
Black
-
Red
Green
Images not contractually binding
1)
g
2)
h
OFF
N
L1
L2
230 V
50 Hz
N L1 L2
120 V
60 Hz
1)
2)
3)
4)
5)
6)
EN
f
a
=
b
=
23

Publicidad

Tabla de contenido
loading

Tabla de contenido