2.2

Technical data

TIH 100m
Voltage (±10%)
Recommended line protection
Power consumption (maximum)
Temperature control
Probe type
Probe maximum temperature
Time mode
Power range
Demagnetization
Overall dimensions (w x d x h)
Area between supports (width x height)
Coil diameter
Weight (with yokes)
Workpiece maximum weight
Maximum heating temperature
m20*
Standard yoke dimensions:
56 x 56 x 296
(2.2 x 2.2 x 11.7 in)
28 x 28 x 296 mm
(1.1 x 1.1 x 11.7 in)
14 x 14 x 296 mm
(0.6 x 0.6 x 11.7 in)
*m
represents the weight (kg) of the heaviest SRB 231 bearing that can be
20
heated from 20 to 110 °C (68 to 230 °F) in 20 minutes.
SKF TIH 100m
TIH 100M/230V : 230V / 50-60Hz
TIH 100M/MV : 400-460V / 50-60Hz
16 A fuse rating for 230 V
10 A fuse rating for 400-460 V
3.6 kVA for 230 V
4.0-4.6 kVA for 400-460 V
0-250 °C (32-482 °F); in steps of 1°
Thermocouple, K type
250 °C (482 °F)
0-60 minutes; in steps of 0.1 minute
100%- 50%
automatic; residual magnetism <2A/cm
570 x 230 x 350 mm
(22.4 x 9.0 x 13.7 in)
155 x 205 mm (6.1 x 8.0 in)
110 mm (4.3 in)
For minimum bearing bore diameter of
120 mm (4.7 in)
42 kg (92 lbs)
Bearing: 120 kg (264 lbs)
Solid component: 60 kg (132 lbs)
approx. 400 °C (752 °F)
97 kg (bearing 23156)
For minimum bearing bore diameter of:
80 mm (3.1 in)
40 mm (1.6 in)
20 mm (0.8 in)
9