Remove the cover and fix the automation in a stable and leveled way to the wall using the measurements shown in the
figure; refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation
screw M8 x
50)
Note: if necessary, you can change the measure H, between the automation and the door,
codes listed in the
table.
(H)
PBBS2 automation
30
001PBBA01 + 001PBBA06
47
001PBBA01
64
001PBBA01 + 001PBBA08
PRE-CHARGING OF THE CLOSING SPRINGS
Tighten the screw [a] and compress the springs of about X = 10 mm, as shown in the figure.
Move the door manually, and verify the correct opening and closing force.
Adjust the opening mechanical stop inside the sliding arm.
CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.