8. ELECTRONIC CONTROL ADJUSTEMENT
The electronic control has 4 buttons and 4 alphanumeric displays to set all the necessary adjustments.
After turning on the electronic control, the display shows the word "MENU". The operation of the four keys are indicated in
the table.
Keys
Description
ENTER
Select button, each time you press the button you enter on the
selected parameter.
Save button, pressing for 1 seconds you "SAVE" the selected value.
MENU = Main parameters menu
MEM = Memory management menu
ADV = Advanced parameters menu
SEL = Function selector menu
INFO = Information and diagnostics menu
ESC
Exit button, exit from all the parameter or exit from the menu.
Scroll button, each press selects a menu item or increases the value
of the selected item.
Scroll button, each press selects a menu item or reduces the value of
the selected item.
8.1 BASIC SETTINGS MENU
Using the buttons ↑ and ↓ choose MENU, press ENTER to select and adjust the following main parameters:
Display
Description
DOOR
Setting the automation type. Choose between the following values:
DOOR TYPE
SW2 = SW2 automation PBB2 (LIGHT)
SW4 = SW4 automation PBBS2 (SPRING)
SW5 = SW5 automation PBB3 (HEAVY)
OPEN
Setting the opening direction. Choose between the following values:
OPENING
← = door hinged on left
DIRECTION
→ = door hinged on right
ARM
Setting the type of arm. Choose between the following values:
ARM TYPE
PULL = sliding arm
PUSH = articulated arm
VOP
Opening speed setting. Choose between the minimum and maximum:
OPENING
minimum value = 15 deg/s
SPEED
maximum value = 70 deg/s
VCL
Closing speed setting. Choose between the minimum and maximum:
CLOSING
minimum value = 100 mm/s
SPEED
maximum value = 700 mm/s
TAC
Open door time setting. Choose between the minimum and maximum:
CLOSING TIME
NO = the door is always open
minimum value = 1 s
maximum value = 30 s
PUSH
Force setting. Choose between the minimum and maximum:
MOTOR
minimum value = 1
POWER
maximum value = 10
LEAF
Setting the weight of the door. Choose between the following values:
DOOR WEIGHT
MIN = light door
MED = medium door
MAX = heavy door
RAMP
Set the acceleration time. Choose between the minimum and maximum values:
ACCELERATION
minimum value = 100 ms (maximum acceleration)
TIME
maximum value = 2000 ms (minimum acceleration)
BTMD
Setting operation of battery power device, in absence of electricity. Choose between the following
BATTERY
values:
MODE
NO = battery not connected
EMER = emergency open
CONT = continuation of normal operation of the door, with last cycle of opening
Note: the number of operations with battery, depends on the efficiency of the battery, the weight of
the doors and the present friction.
FA00008-EN v.7 – 05/2017
23
Factory settings
SW2
PULL
50
50
1
10
MED
400
NO