9. START-UP PROCEDURE OF THE AUTOMATIC SWING DOOR
9.1 Preliminary checks.
At the end of the installation, move the doors manually and make sure that operation is smooth and without friction. Check
the solidity of the structure and the proper attachment of all the screws. Check the correctness of all electrical connections.
Make sure you have installed the mechanical stop of the open door.
9.2 Before connecting any security devices, leave the jumper on terminals safety (41-6A, 41-8A).
9.3 Giving power supply and connect the battery, if present.
Note: every time you switch on the automation performs a self-test (from 3 to 30 seconds). The first opening and closing
cycle is at low speed to allow the automatic learning.
9.4 To ensure that the electronic control has the factory settings, restore via the menu:
MEM> FSET> YES (confirm by pressing ENTER for 1 second).
Note: if the door is hinged on right, set as follow: MENU > OPEN > → (confirm by pressing ENTER for 1 second).
Note: if the door is with articulated arm, set as follow: MENU > ARM > PUSH (confirm by pressing ENTER for 1 second).
Note: if the door is PBBS2 (SPRING model), set as follow: MENU > DOOR > SW4 (confirm by pressing ENTER for 1 second).
Note: if the door is PBB3 (HEAVY model), set as follow: MENU > DOOR > SW5 (confirm by pressing ENTER for 1 second).
9.5 Perform the menu settings as described in Chapter 8. Use OPEN button to perform the opening door, and verify the
correct operation of the door.
Note: the automation automatically detects any obstacles during the closing movement (reversal movement) and opening
(stopping movement).
9.6 If present, connect the electric lock of the door to the terminals (-LK \ +LK) of electronic control, and make the settings
available in the ADV menu.
9.7 Connect one at a time, control
and safety devices to protect the
opening and closing cycle of the
door, as described in Chapter 7.6,
and verify proper operations.
Note: verify that the opening access
is properly protected by safety
sensors, in accordance with the
requirements
of
the
European
standard EN16005 (annex C).
9.8 At the end of the automation starting, deliver to the owner the user
instructions, including all warnings and information necessary to maintain the
security and functionality of the automatic door.
9.9 FLUO-SW automations are feature of label containing the required
information by European standards EN16005 and EN60335-2-103.
Note: the manufacturer of the automatic swing door have to add his own
label identifying the installation.