4.5 INSTALLATION OF PBB3 AUTOMATION WITH 001PBBA01 SLIDING ARM
Use the sliding arm to pull with doors which open inside (view from the automation).
Remove the cover and fix the automation in a stable and leveled way to the wall using the measurements shown in the
figure; refer to the axis of the door hinges.
Fix the sliding arm on the door as shown in the figure. Insert the sliding arm in the guide and fix to the automation.
Note: if necessary, you can change the measure H, between the automation and the door,
codes listed in the
table.
(H)
PBB3 automation
28
001PBBA01
45
001PBBA01 + 001PBBA08
62
001PBBA01 + 001PBBA09
Move the door manually, and verify the correct opening and closing smoothly.
Adjust the opening mechanical stop inside the sliding arm.
CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.
FA00008-EN v.7 – 05/2017
12
by replacing the spacer, using the
CAME S.p.A.