CAME FLUO-SW Manual De Ensamblado E Instalación página 64

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DISPLAY SEL FLASH WARNING
W001
1
Encoder error
W002
1
Motor short circuit
W003
1
Motor control error
W010
2
Direction reversed
W011
2
Running too long
W012
2
Running too short
W013
2
Overrun
W100
-
-
Programming error (CB03)
W103
-
-
Programming error (FSD1)
W127
-
-
Automation reset
W128
on
No power supply
W129
1
No battery
W130
1
Low Battery
W140
3
6A safety test failure
W142
3
8A safety test failure
W145
4
Motor overtemperature (first step)
W146
4
Motor overtemperature (second step)
W150
2
Obstacle in opening
W151
2
Obstacle in closing
W152
2
Door locked open
W153
2
Door locked closed
W156
2
Door moved manually
W160
1
Synchronization error
W256
-
Power on
W257
-
Firmware update
W320
on
Signaling of maintenance
W330
1
Tuning between motor and electronics
FA00008-EN v.7 – 05/2017
CHECK
Check encoder connection
Check the connection of the motor
Electronic control failure
Check the presence of obstacles
Check the connection between the motor and leaf
Check the presence of obstacles
Check the mechanical stops
Repeat the programming procedure in MEM > FW menu
Repeat the programming procedure in SEL > FW menu
The automation performs a self-test
Check the power supply
Check the battery connection
Replace or recharge the battery
Check the safety sensor connection
Check the safety sensor connection
The door reduces the speed
The door stops
Check the presence of obstacles
Check the presence of obstacles
Check the presence of locks
Check the presence of locks
Wait about 5 seconds
Check the ADV > SYNC menu
-
-
Check the INFO > SERV menu
Wait about 3-30 seconds
30
CAME S.p.A.

Publicidad

Tabla de contenido
loading

Tabla de contenido