Display
Description
FW
Programming procedure of function selector.
FIRMWARE
Insert the micro SD memory in the electronic control.
UPGRADE
From this menu, choose the firmware version you want (from 0200 to - - - -).
Press ENTER until it starts the programming procedure that lasts about 30 seconds (the display shows
"WAIT • • • •"), at the end the display shows "SAVE".
After the procedure, remove the micro SD memory from the electronic control and store it for future
use.
Note: in the case of programming error or missing firmware (W103), proceed as follows:
the
power supply, insert the micro SD memory, give power supply, and repeat the programming
procedure from this menu.
VER
Displaying the firmware version of function selector (eg = 0200).
VERSION
TIN
You can upload the badges and numeric codes used in another automation, already stored in the
TAG INPUT
micro SD memory. Choose between the following values:
NO = no upload
YES = upload the badges and numeric codes from the micro SD memory
TOUT
You can save the stored badges and numeric codes in the micro SD memory. Choose between the
TAG OUTPUT
following values:
NO = no save
YES = save the stored badges and numeric codes in the micro SD memory
8.5 INFORMATION AND DIAGNOSTICS MENU
Using the buttons ↑ and ↓ select INFO, press ENTER to select and adjust the following information and diagnostics menu.
Display
Description
SHOW
Displaying information of warning and faults. Choose between the following values:
DISPLAY
CONT = the display shows the active contacts of the terminal blocks and the alarms.
INFO
WARN = the display shows the alarms only.
VER
Displaying the firmware version of electronic control (eg = 0200).
VERSION
CYCL
Shows the number of cycles of the door (1 = 1.000 cycles, 9000 = 9.000.000 cycles).
CYCLES
SERV
Enabling the signaling of routine maintenance of the door.
SERVICE
NO = no signaling
SIGNAL
1 = 1.000 cycles / 9000 = 9.000.000 cycles
LOG
You can save the following information in the micro SD memory (swing_log.txt): the last 20 warnings,
INFO
the menu settings, and the electronic devices connected to automation. Choose between the following
OUTPUT
values:
NO = no save
YES = save the information in the micro SD memory
WARN
Displaying of the last 10 warnings (the warning number 0 is the last):
WARNING
0.xxx / 1.xxx / 2.xxx / 3.xxx / 4.xxx / 5.xxx / 6.xxx / 7.xxx / 8.xxx / 9.xxx
LIST
FA00008-EN v.7 – 05/2017
29
Factory settings
- - - -
disconnect
- - - -
NO
NO
Factory settings
CONT
- - - -
0000
0000
NO
0. - - -
CAME S.p.A.