CAME FLUO-SW Manual De Ensamblado E Instalación página 62

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display
Description
TMAS
It is possible to create master badge and master numeric code that allows the saving of the badges
TAG MASTER
and the numeric codes, without the use of the menu. Choose from the following values.
NO = no saving
MMOD = creation of the master badge and master numeric code to saving badges and numeric codes
for function selector activation: proceed as SMOD.
MOPE = creation of the master badge and master numeric code to saving the badges and numeric
codes of opening priority: proceed as SMOD.
Note: if the badge and the numeric code is not recognized the display shows the message UNKN, or if
the badge and the numeric code is already stored will show the message NOK.
- The use of the master badge is the following:
- approach the master badge to the function selector (in front of the NFC symbol), the buzzer emits 2
beeps at the beginning of the storage procedure,
- approach the badges, that you want to store, one at a time, to the function selector (in front of the
NFC symbol), the buzzer emits 1 beep of confirmation storage,
- wait for 20 seconds,
Note: if the badge and the numeric code is not stored, the buzzer emits no beeps.
TERA
How to erase all stored badges and numeric codes. Choose between the following values:
TAG TOTAL
NO = no erase
ERASE
YES = cancellation of all badges and numeric codes
SAM1
First setting of function selector, when the 1-G1 (1-G2) contact becomes closed. Set the menu ADV >
SELECTOR
STG1 (STG2) > SAM.
AUTOMATIC
Connect the contact of a clock to 1-G1 (1-G2) terminals, and choose between the following values:
MODE
OPEN = open door
AUTO = automatic bi-directional operation
CLOS = closed door
1D = automatic one-way operation
SAM2
Second setting of function selector, when the 1-G1 (1-G2) contact becomes open. Set the menu ADV
SELECTOR
> STG1 (STG2) > SAM.
AUTOMATIC
Connect the contact of a clock to 1-G1 (1-G2) terminals, and choose between the following values:
MODE
OPEN = open door
AUTO = automatic bi-directional operation
CLOS = closed door
1D = automatic one-way operation
FA00008-EN v.7 – 05/2017
the buzzer
emits
2 beeps at the end of the storage
procedure.
28
Factory settings
NO
NO
CLOS
CLOS
CAME S.p.A.

Publicidad

Tabla de contenido
loading