Sime MURELLE 25/55 OF ErP Manual De Instrucciones página 86

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

reaches. a. maximum. of. 55°C.. During. the.
function.all.the.other.heating.demands.are.
ignored. (heating,. sanitary,. antifreeze. and.
chimney.sweep)..During.the.functioning.the.
display. shows. the. remaining. days. for. the.
completion.of.the.function.(example.mains.
4.5.3  Pump high efficiency diagnose and remedy (fig. 23/b)
LED diagnose and remedy
Led color
Continuous green
Red/green blinking
Red blinking
No LED
86
digits. -15. =. 15. days. lack. to. the. end. of. the.
function)..
The. diagram. fig.. 23. reports. the.
development.of.the.curve.
ATTENTION:
-   Observe  the  relevant  standards  and 
Meaning
Diagnostic
Normal.running
Pump.run.as.
expected.or.is.faced.
to.a.phenomenon.
that.shortly.affects.
its.running
Abnormal.situation.
Pump.will.restart.
(pump.functional.
by.itself.after.the.
but.stopped)
abnormal.situation.
disappeared
Stopped.(e.g..pump.
Reset.the.pump.
blocked)
Check.LED.signal
No.power.supply
No.voltage.
on.electronics
regulations of the floor manufacturer!
-   Proper  functioning  is  ensured  only 
when  the  plant  is  correctly  installed 
(hydraulic  system,  electrical  installa-
tion, settings)! If not observed, the floor 
might get damaged!
LED
Cause
Remedy
Normal.operation
1..Undervoltage.or.
1..Check.voltage.supply:.
Overvoltage:.
195V<U<253V
. U<160V.or.U>.253V
2..Module.overvoltage:.
2..Check.water.&.ambient.
. T°.inside.motor.too.high
Pump.cannot.restart.
Change.pump
itself.due.to.a.permanent.
failure
1). Pump.is.not.connected.to.
1). Check.cable.connection
power.supply
2). LED.is.damaged
2). Check.if.pump.is.runnning
3). Electronics.are.damaged
3). Change.pump
Fig..23/b