the. on/off. taps. supplied. in. kit. optional. on.
the.heating.system.delivery/return.pipes..
WARNING: Failure to clean the heat
system or add an adequate inhibitor inva-
lidates the device's warranty.
Gas. connections. must. be. made. in. accor-
dance. with. current. standards. and. regula-
tions.. When. dimensioning. gas. pipes. from.
the. meter. to. the. module,. both. capacity.
volume. (consumption). in. m
density.must.be.taken.into.account..
The. sections. of. the. piping. making. up. the.
system. must. be. such. as. to. guarantee.
a. supply. of. gas. sufficient. to. cover. the.
maximum. demand,. limiting. pressure. loss.
between. the. gas. meter. and. any. apparatus.
1...Visualizzazione.temperatura.esterna
being.used.to.not.greater.than:
....solo.con.sonda.esterna.collegata
–. 1.0.mbar.for.family.II.gases.(natural.gas);
–. 2.0. mbar. for. family. III. gases. (butane. or.
propane).
An.adhesive.data.plate.is.sticked.inside.the.
front.panel;.it.contains.all.the.technical.data.
2...Visualizzazione.temperatura.sonda
identifying.the.boiler.and.the.type.of.gas.for.
.....riscaldamento.(SM)
which.the.boiler.is.arranged.
2.3.1
Filter on the gas pipe
The.gas.valve.is.supplied.ex.factory.with.an.
3...Visualizzazione.temperatura.sonda
inlet.filter,.which,.however,.is.not.adequate.
.....sanitario.(SS).solo.per.caldaie.istantanee
to.entrap.all.the.impurities.in.the.gas.or.in.
gas.main.pipes..
To. prevent. malfunctioning. of. the. valve,. or.
in. certain. cases. even. to. cut. out. the. safety.
device. with. which. the. valve. is. equipped,.
install.an.adequate.filter.on.the.gas.pipe.
4...Visualizzazione.temperatura.sonda
.....ausiliaria.o.sonda.bollitore.(SB)
2.5
SYSTEM FILLING
Filling.of.the.boiler.and.the.system.is.done.
by.the.charge.load.faucet.(fig..24/a)..
The.charge.pressure,.with.the.system.cold,.
must.be.between.1 and 1.5 bar..
5. .Visualizzazione.temperatura.sonda
.....fumi
Filling. must. be. done. slowly. so. as. to. allow.
any. air. bubbles. to. be. bled. off. through. the.
air.valves..
2.5.1
Emptying the system (fig. 5/a)
6..Visualizzazione.temperatura
To.drain.the.system,.turn.off.the.boiler.and.
.....riscaldamento.riferita.al.primo.circuito
to.loosen.with.one.key.from.13.the.appro-
priate.download.of.some.turns.(fig..5/a).
2.6
FLUES/CHIMNEYS
7. Visualizzazione.temperatura
A.chimney.or.flue.for.the.evacuation.of.the.
.....riscaldamento.riferita.al.secondo.circuito
combustion. products. into. the. atmosphere.
must.correspond.to.the.requisites.prescri-
bed.by.the.laws.in.force..
2.11
ELECTRICAL WIRING
8. .Visualizzazione.corrente
If.you.must.replace.the.electric.power.cable.
.....di.ionizzazione.in.µA
supplied.with.the.boiler,.order.it.exclusively.
from.Sime..
The. power. supply. must. be. single-phase.
70
3
/h. and. gas.
9. .Visualizzazione.corrente.al
.....modulatore.in.mA
10. .Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
11. .Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
12. .Visualizzazione.codice.errore
.......ultima.anomalia
230V. -. 50. Hz. through. a. main. switch. pro-
tected.by.a.fuse.with.a.distance.of.at.least.3.
mm.between.contacts.
The boiler must be connected with an effi-
cient grounding system. SIME shall not be
held liable for injury or damage resulting
13...Visualizzazione.codice.errore
from failure to ground the boiler.
.......penultima.anomalia
ATTENTION: Before every intervention
on the boiler, cut off the electricity sup-
ply by means of the main switch of the
system, since even if the boiler is "OFF",
the electrical panel remains connected to
14...Visualizzazione.numero.totale
the electricity.
.......delle.anomalie
2.11.1 Chronothermostat
connection
Connect. the. chronothermostat. as. indica-
ted. in. the. boiler. electrical. diagram. (see.
15. .Contatore.accessi.parametri
.......installatore.(es..140.accessi)
paragraph. 2.12). after. having. removed. the.
existing.bridge..
The. chronothermostat. to. be. used. must. be.
of. a. class. conforming. to. the. standard. EN.
607301.(clean.electrical.contact).
16. Contatore.accessi.parametri
2.11.2 Remote control SIME HOME
.......OEM.(es..48.accessi)
connection (optional)
The. boiler. is. designed. for. connection. to. a.
Fig..5/a
remote. control. unit. SIME.HOME,. supplied.
on.request.(code.8092280/81)..
The.remote.control.unit.SIME.HOME.allows.
for. complete. remote. control. of. the. boiler..
The. boiler. display. will. show. the. following.
message:
For.installation.and.use.of.the.remote.con-
trol,.follow.the.instructions.in.the.package.
NOTE: Ensure PAR 10 set to 1 (PAR 10 = 1).
2.11.3 External sensor
connection
The.boiler.is.designed.for.connection.to.an.
external. temperature. sensor,. supplied. on.
request. (code. 8094101),. which. can. auto-
matically.regulate.the.temperature.value.of.
the.boiler.output.according.to.the.external.
temperature..
For.installation,.follow.the.instruction.in.the.
package..It.is.possible.to.make.corrections.
to.the.values.read.by.the.drill.acting.on.the.
PAR 11.