Electrical Wiring - Sime MURELLE 25/55 OF ErP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

the. on/off. taps. supplied. in. kit. optional. on.
the.heating.system.delivery/return.pipes..
WARNING:  Failure  to  clean  the  heat 
system or add an adequate inhibitor inva-
lidates the device's warranty.
Gas. connections. must. be. made. in. accor-
dance. with. current. standards. and. regula-
tions.. When. dimensioning. gas. pipes. from.
the. meter. to. the. module,. both. capacity.
volume. (consumption). in. m
density.must.be.taken.into.account..
The. sections. of. the. piping. making. up. the.
system. must. be. such. as. to. guarantee.
a. supply. of. gas. sufficient. to. cover. the.
maximum. demand,. limiting. pressure. loss.
between. the. gas. meter. and. any. apparatus.
1...Visualizzazione.temperatura.esterna
being.used.to.not.greater.than:
....solo.con.sonda.esterna.collegata
–. 1.0.mbar.for.family.II.gases.(natural.gas);
–. 2.0. mbar. for. family. III. gases. (butane. or.
propane).
An.adhesive.data.plate.is.sticked.inside.the.
front.panel;.it.contains.all.the.technical.data.
2...Visualizzazione.temperatura.sonda
identifying.the.boiler.and.the.type.of.gas.for.
.....riscaldamento.(SM)
which.the.boiler.is.arranged.
2.3.1 
Filter on the gas pipe
The.gas.valve.is.supplied.ex.factory.with.an.
3...Visualizzazione.temperatura.sonda
inlet.filter,.which,.however,.is.not.adequate.
.....sanitario.(SS).solo.per.caldaie.istantanee
to.entrap.all.the.impurities.in.the.gas.or.in.
gas.main.pipes..
To. prevent. malfunctioning. of. the. valve,. or.
in. certain. cases. even. to. cut. out. the. safety.
device. with. which. the. valve. is. equipped,.
install.an.adequate.filter.on.the.gas.pipe.
4...Visualizzazione.temperatura.sonda
.....ausiliaria.o.sonda.bollitore.(SB)
2.5 
SYSTEM FILLING
Filling.of.the.boiler.and.the.system.is.done.
by.the.charge.load.faucet.(fig..24/a)..
The.charge.pressure,.with.the.system.cold,.
must.be.between.1 and 1.5 bar..
5. .Visualizzazione.temperatura.sonda
.....fumi
Filling. must. be. done. slowly. so. as. to. allow.
any. air. bubbles. to. be. bled. off. through. the.
air.valves..
2.5.1 
Emptying the system (fig. 5/a)
6..Visualizzazione.temperatura
To.drain.the.system,.turn.off.the.boiler.and.
.....riscaldamento.riferita.al.primo.circuito
to.loosen.with.one.key.from.13.the.appro-
priate.download.of.some.turns.(fig..5/a).
2.6 
FLUES/CHIMNEYS
7. Visualizzazione.temperatura
A.chimney.or.flue.for.the.evacuation.of.the.
.....riscaldamento.riferita.al.secondo.circuito
combustion. products. into. the. atmosphere.
must.correspond.to.the.requisites.prescri-
bed.by.the.laws.in.force..
2.11 
ELECTRICAL WIRING
8. .Visualizzazione.corrente
If.you.must.replace.the.electric.power.cable.
.....di.ionizzazione.in.µA
supplied.with.the.boiler,.order.it.exclusively.
from.Sime..
The. power. supply. must. be. single-phase.
70
3
/h. and. gas.
9. .Visualizzazione.corrente.al
.....modulatore.in.mA
10. .Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
11. .Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
12. .Visualizzazione.codice.errore
.......ultima.anomalia
230V. -. 50. Hz. through. a. main. switch. pro-
tected.by.a.fuse.with.a.distance.of.at.least.3.
mm.between.contacts.
The boiler must be connected with an effi-
cient grounding system. SIME shall not be 
held liable for injury or damage resulting 
13...Visualizzazione.codice.errore
from failure to ground the boiler. 
.......penultima.anomalia
ATTENTION:  Before  every  intervention 
on  the  boiler,  cut  off  the  electricity  sup-
ply  by  means  of  the  main  switch  of  the 
system,  since  even  if  the  boiler  is  "OFF", 
the electrical panel remains connected to 
14...Visualizzazione.numero.totale
the electricity.
.......delle.anomalie
2.11.1  Chronothermostat 
connection
Connect. the. chronothermostat. as. indica-
ted. in. the. boiler. electrical. diagram. (see.
15. .Contatore.accessi.parametri
.......installatore.(es..140.accessi)
paragraph. 2.12). after. having. removed. the.
existing.bridge..
The. chronothermostat. to. be. used. must. be.
of. a. class. conforming. to. the. standard. EN.
607301.(clean.electrical.contact).
16.  Contatore.accessi.parametri
2.11.2  Remote control SIME HOME
.......OEM.(es..48.accessi)
 connection (optional)
The. boiler. is. designed. for. connection. to. a.
Fig..5/a
remote. control. unit. SIME.HOME,. supplied.
on.request.(code.8092280/81)..
The.remote.control.unit.SIME.HOME.allows.
for. complete. remote. control. of. the. boiler..
The. boiler. display. will. show. the. following.
message:
For.installation.and.use.of.the.remote.con-
trol,.follow.the.instructions.in.the.package.
NOTE: Ensure PAR 10 set to 1 (PAR 10 = 1).
2.11.3  External  sensor 
connection
The.boiler.is.designed.for.connection.to.an.
external. temperature. sensor,. supplied. on.
request. (code. 8094101),. which. can. auto-
matically.regulate.the.temperature.value.of.
the.boiler.output.according.to.the.external.
temperature..
For.installation,.follow.the.instruction.in.the.
package..It.is.possible.to.make.corrections.
to.the.values.read.by.the.drill.acting.on.the.
PAR 11.