Integrated cleaning program
the integrated cleaning program removes residues, including coffee oil residues, that
cannot be eliminated by hand. It takes a total of approximately 15 minutes.
Prerequisite: The appliance is switched off.
Caution!
–
Run the integrated cleaning program every 2 months or after approxi-
mately 200 brewed cups of coffee, at the latest however run the program
when the symbol for cleaning
–
Only use the cleaning tabs from Melitta
these tabs are precisely matched to the Melitta
cleaning agents can damage the appliance.
Run the integrated cleaning program as follows:
1 Flip up the lid of the water reservoir (Fig. A, no. ) and pull the water
reservoir up and out of the appliance. Fill the water reservoir to the Max.
mark and re-insert it.
2 simultaneously press the button for single-cup dispensing
On / Off button
3 the symbol for cleaning
the symbol for the drip tray
4 empty the drip tray and the coffee grounds container.
5 Re-insert the drip tray without the coffee grounds container and place the
coffee grounds container under the outlet.
→
First two automatic rinsing cycles are executed.
then the standby symbol is illuminated
6 Reach into the recess on the right side of the appliance (Fig. A, no. ) and
pull off the cover to the right.
7 Press and hold the red button on the handle of the brewing unit
(Fig. B, no. ) and turn the handle clockwise to the stop (approximately
75°).
Heft_Solo_EU.indd 61
is illuminated in the display.
for more than 2 seconds.
flashes during the entire process.
flashes.
for automatic coffeemakers.
®
sOLO. use of other
®
and the
.
09.07.2009 15:47:42