Installation Of The Indoor Unit; Selecting An Installation Location; Dimensions And Service Space; Inspecting, Handling And Unpacking The Unit - Rotex RKHBH008AA Manual De Instalación

Ocultar thumbs Ver también para RKHBH008AA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 150
I
NSTALLATION OF THE INDOOR UNIT

Selecting an installation location

The unit is to be wall mounted in an indoor location that meets the
following requirements:
The installation location is frost-free.
The space around the unit is adequate for servicing. (See
figure 2).
The space around the unit allows for sufficient air circulation.
There is a provision for condensate drain (only for RKHBX
models with drain pan kit EKHBDP) and pressure relief valve
blow-off.
The installation surface is a flat and vertical non-combustible
wall, capable of supporting the operation weight of the unit (see
"Technical specifications" on page 29).
There is no danger of fire due to leakage of inflammable gas.
All piping lengths and distances have been taken into
consideration.
Requirement
Maximum allowable refrigerant piping length between
outdoor unit and indoor unit
Minimum required refrigerant piping length between
outdoor unit and indoor unit
Maximum allowable height difference between
outdoor unit and indoor unit
Maximum allowable distance between the 3-way
valve and the indoor unit (only for installations with
domestic hot water tank).
Maximum allowable distance between the domestic
hot water tank and the indoor unit (only for
installations with domestic hot water tank). The
thermistor cable supplied with the domestic hot water
tank is 12 m in length.
The equipment is not intended for use in a potentially explosive
atmosphere.
If the installation is equipped with a domestic hot water
NOTE
tank (optional), please refer to the domestic hot water
tank installation manual.

Dimensions and service space

Unit of measurement: mm
Dimensions of the wall bracket
10
163
Dimensions of the unit, see figure 3
1
Flexible drain hose
2
Water outlet connection
3
Water inlet connection
4
Refrigerant liquid connection
5
Refrigerant gas connection
Required service space, see figure 2.
Installation manual
8
Value
30 m
3 m
20 m
3 m
10 m
10
10
163

Inspecting, handling and unpacking the unit

The indoor unit is packed in a cardboard box, fixed by straps on
a wooden pallet.
At delivery, the unit must be checked and any damage must be
reported immediately to the carrier claims agent.
Check if all indoor unit accessories (see "Accessories" on
page 2) are enclosed.
Bring the unit as close as possible to its final installation position
in its original package in order to prevent damage during
transport.
The indoor unit weighs approximately 50 kg and should be lifted
by two persons using the two lifting bars provided.
Do not grasp the switch box or piping to lift the unit! Two
lifting bars are provided to lift the unit.
Indoor unit for air to water heat pump system
RKHBH/X008AA
4PW50203-1A

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Rkhbx008aaRkhbh016abRkhbx016ab

Tabla de contenido