Range Technical Data Table; Instructions For Installation; Installation; Laws, Technical Rules And Norms - Lotus PC-94ET Guia Para La Intalación E Instrucciones De Uso

Cocinas a gas para uso profesional
Ocultar thumbs Ver también para PC-94ET:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DIMENSIONS
MODELS
cm
80x90x90h
CF4-98ET
80x90x90h
CFQ4-98ET
CFC4-98ET
80x90x90h
CF6-912ETV
120x90x90h
CFQ6-912ETV
120x90x90h
CF6-912ET
120x90x90h
120x90x90h
CFQ6-912ET
160x90x90h
CF8-916ETV
120x90x90h
CFQ8-916ETV
160x90x90h
CF8-916ET
CFQ8-916ET
120x90x90h
CFV4-98ET
80x90x90h
80x90x90h
CFVQ4-98ET
80x90x90h
CFVC4-98ET
CFV6-912ETV
120x90x90h
CFVQ6-912ETV
120x90x90h
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
GB
IT

RANGE TECHNICAL DATA TABLE

POWER SUPPLY
ABSORPTION
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz
400V/3N 50/60 Hz

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

IE
CH
MAXIMUM
MAXIMUM
POWER
A
kW
37,83
20,7
42,17
22,7
(34,78+14,8)
(16 + 6,7)
36,96
20,3
45,2
27,7
(14,8+30,4)
(6,7+21)
49,6
30,7
(14,8+34,8)
(6,7+24)
45,2
30,2
(14,8+30,4)
(9,2+21)
49,6
33,2
(14,8+34,8)
(9,2+24)
60,4
37,2
(30+30,4)
(16,2+21)
67
41,2
(32,2+34,8)
(17,2+24)
60,4
41,4
(30+30,4)
(20,4+21)
67
45,4
(32,2+34,8)
(21,4+24)
37,97
19,32
42,32
21,32
(24,93+17,39)
(12+9,32)
37,1
18,92
38,49
26,32
42,84
29,32
(34,78+8,06)
(24+5,32)
38
Emissivity
POWER SUPPLY
dB
CABLE (Silicone)
5x6 mm²
/
5x6 mm² +5x6
/
mm²
/
5x6 mm²
5x4 mm² +5x4
/
mm²
5x6 mm² +5x6
/
mm²
5x4 mm² +5x4
/
mm²
5x6 mm² +5x6
/
mm²
5x4 mm² +5x4
/
mm²
5x6 mm² +5x6
/
mm²
5x4 mm² +5x4
/
mm²
5x6 mm² +5x6
/
mm²
<70
5x6 mm²
<70
5x4 mm² +5x4 mm²
<70
5x6 mm²
<70
5x6 mm²
<70
5x6 mm² +5x6 mm²

Publicidad