Description Of The Product; Technical Description; Preliminary Checks - EB TECHNOLOGY START S10 Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1
Introduction
START S10 is a new control unit with time counter and digital slow down. It has been designed for different uses: for one-
two motors gates, low tensions motors mechanical and oleodynamic. It has been used the most advanced technologies to
guarantee the protection against interferences, the flexibility and the variety of functions.
1.1

Description of the product

Self-learning of the working time
automatic battery charter
Reading and program with DISPLAY
Check of the motors, Max 80W totally
Adjustment of the motor speed and slow down
Obstacle detection for separate motors and separate speed and slow down for the motors
Code managing (up to 197 remote controls)
Test for safety devices before each opening
Opto-isolated inputs, excepted for PARTIAL OPENING
1.2

Technical description

Maximum power with trasformer: 100 VA
Protection Fuse
Dimensions
Weight
2
Premises
Remember that systems for automatic gates and doors must be installed by highly qualifi ed technicians only and in full
compliance with current law.
Before starting installation, check that the mechanical consistency and sturdiness of the gate or door, check that the
mechanical stops are suitable to stop the movement of the gate or door even if the electrical limit switches should fail or
during manual operations.
2.1

Preliminary checks

Making the correct choice of installation is essential to ensuring adequate safety and good protection against atmospheric
agents. Remember that the control unit contains powered parts and electronic components which by their very nature are
sensitive to infi ltrations and moisture. The control unit is supplied in a container which guarantees an IP55 protection rating
if adequately installed. Install the control unit on a permanent surface that is perfectly flat, adequately protected against
impacts and at least 40 cm off the ground.
The cables must enter the control unit from the bottom only; we recommend using wire leads and water-tight connections.
When using tubing that could fi ll up with water or if the tubing comes from an underground well, the wires must enter a fi rst
shunting box placed at the same height as the control unit and then, from there, the wires must be passed into the container
holding the control unit, again entering from the bottom.
This prevents any evaporation of the water in the tubing from forming condensation inside the control unit itself.
80 W
F1: 3,15 A ritardato - F2: 1,6 A - F3: 8 A
b170 x h90 x p30 mm
250 g (transformer not included)