Description of the electrical connection

230 Vac
230 Vac
Lamp
MOT common
MOT close
MOT open
Antenna
Common 1
Com2 / -12Vdc 10
+ 12Vdc 11
Stop 12
Foto 13
Lso 14
Lsc 15
Start 16
Pedestrian 17
24Vac 18
+24Vdc / 24Vac 19
C. Light 20
C. Light 21
Alt 22
Alt 23
1
Electrical power supply 230 Vac 50 Hz
2
Electrical power supply 230 Vac 50 Hz
3
Output for fl ashing or courtesy light 230 Vac, maximum power rating of
the lamp 100W.
4
5
Output for connection of COMMON motor pole
6
Output for connection of CLOSING motor pole
7
Output for connection of OPENING motor pole
8
Input for antenna signal (end of antenna hot wire)
Common for all inputs:
9
services, safety devices, coaxial antenna braid
Output -12/24 Vdc (See Phar. 2.6), Common 2
Output +12 Vdc maximum current 50mA (positive)
STOP input
Input for photocell
(PHOTO safety trips intervention only when closing)
Input for opening limit switch
Input for closing limit switch
Input for step-by-step START
Input for step-by-step control of partial PEDESTRIAN opening
(same setting as START)
Output 24Vac (See Phar. 2.6)
Output + 24Vdc, 24Vac (See Phar. 2.6)
dry-contact contacts for light or photocell TEST
or fl ashing light without intermittence circuit board
NC stop safety edge + inversion for 1.5 seconds