TROUBLESHOOTING

Troubleshooting
1
The indicator
flashed.
2
The indicator
is on.
Indicator
stays on even after pressing
3
button.
4
Indicator
flashes.
5
Indicator
stays on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 30.12 PL
Causes
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
• Charge failure, battery cannot be
recovered
• Ambient temperature is too low to
charge a LFP battery
Thermal protection
Charger in sleep mode
Charge interrupted by pressing
.
Solutions
• Check that the clamps are connected correctly
• Check that battery is 12 V
• Change the battery and press
restart a charge.
• Charge the battery at milder temperature or press
the
button.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press button
or connect a battery to
the charger to exit sleep mode.
Press
again to restart the charge.