Storage system input (DC)
Voltage range
(1)
Maximum charge/discharge current
Battery type
Communication with Li-Ion batteries
PV array input (DC)
PV array maximum power
MPP Voltage range
Maximum input voltage
(3)
Maximum input current (input 1 / input 2)
MPPT number
Number of inputs (input 1 / input 2)
Auxiliary grid/genset input (AC)
Rated voltage
Voltage range
Nominal frequency
Frequency range
Type of grid
Rated power
Max. temperature for rated power
Maximum current
Power factor
Critical loads output (AC)
Power (25 ºC) 30 min, 2 min, 3s
Maximum current
Rated voltage
(5)
Nominal frequency
(5)
Power factor
Response time of the Back-up function
Performance
Maximum efficiency
Euroefficiency
General data
Cooling system
Air flow rate
Weight
Dimensions (height x width x depth)
Stand-by consumption
Operating temperature
Relative humidity (without condensation)
Protection class
Maximum altitude
Overvoltage category
Markings
EMC and safety regulations
Distribution grid connection regulations
The maximum power supplied by the battery is the battery voltage multiplied by the maximum discharge current.
(1)
list of compatible batteries.
Never exceed this value. Consider the voltage increase of the panels 'Voc' at low temperatures.
(3)
power specified is only available if the sum of the power of the batteries and the photovoltaic power reaches those values.
frequency.
14
(4)
3TL M
40 ~ 450 V
66 A
Lead-acid, Li-Ion (LG, BYD, Pylontech...)
CAN Bus 2.0
11.5 kWp
125 ~ 480 V
550 V
12 A / 12 A
1 / 1
230 V
172 ~ 264 V
50 / 60 Hz
40 ~ 70 Hz
TT / TN
3 kW
40 ºC
13 Arms
0 ~ 1
3,500 / 3,900 / 5,080 W
13 Arms
220 ~ 240 V
50 / 60 Hz
-0.8 ~ 1 ~ 0.8
12 ms
95.5 %
95.1 %
Forced ventilation
45 m
26 kg
470 x 360 x 180 mm
< 10 W
–20 ~ +65 ºC
4 ~ 100 %
IP65
2,000 m
Category III (AC) / Category II (DC)
CE
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4,
EN 61000-3-11, EN 61000-3-12, EN 62109-1, EN62109-2,
AS62040.1, FCC PART 15
DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-
N4105:2011-08, G59/3, G83/2, AS4777.2:2015, IEC 62116, IEC
61727, UNE 206007-1:2013, UNE 206006:2011, UNE 217001
IN:2015,NRS097-2-1, ABNT NBR 16149, ABNT NBR 16150, South
African Grid code, P.O.12.2, G99, EN 50549-1
(2)
ABH2014IQM01_A- Installation and Operation Manual
Unit description
6TL M
(2)
2
6 kW
26 Arms
6,400 / 6,900 / 7,900 W
26 Arms
96 %
95.2 %
/h
3
See the Ingeteam website for the
In off-grid mode, the
(4)
(5)
Configurable voltage and