Sime 25-35 BF TS Manual Del Usaurio página 76

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

and reset the button (fig. 21).
Should the appliance "lock out" again,
please approach the authorised tech-
nical staff.
BURNER RESTART
In case that ignition or operation faults
occur, the main burner "locks out" and
the red lamp lights up on the control
panel. Press the "RESET" button to
restart the ignition conditions until the
flame lights up (fig. 23). This operation
can be repeated 2-3 times at maxi-
mum and in case of failure contact the
authorised technical staff.
ATTENTION: Make sure that
there is fuel in the tank and
that the taps are open. After
each fill up of the tank it is advisable
to interrupt the operation of the
burner for about one hour.
TURNING OFF BOILER
It is sufficient to press the main switch
to turn off the boiler (fig. 19).
Close both the gas-feed pipe tap and
the water tap if the boiler remains
inoperative for a long period.
SYSTEM FILLING
Check periodically that the hydrometer
has pressure values at a switched-off
system of 1 - 1.2 bar.
If the orange water pressure gauge
light turns on inhibiting boiler opera-
tions, restore operations by turning
the supply tap counter-clockwise.
After the operation check that the tap
is properly closed (fig. 24).
Should the pressure exceed the fore-
seen limit, discharge the superfluous
amount by operating on the vent knob
of any radiator.
CLEANING AND MAINTENANCE
At the end of each heating season, it is
essential to have the boiler thoroughly
checked and cleaned out.
Preventive maintenance and
checking of the efficient oper-
ation of the equipment and
safety devices must be carried out
exclusively by the authorised technical
staff.
76
RED WARNING LIGHT ON
ORANGE LIGHT ON
Fig. 22
RESET
BUTTON
RESET
TWICE
ONLY
Fig. 23
OPEN
2
bar
1
3
0
4
Fig. 24

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

35 bf ts pr25-35 ts35 ts prSolo 25 bf tsSolo 35 bf tsSolo 35 bf ts pr ... Mostrar todo

Tabla de contenido