Parts Subject To Wear - Oase Bitron 18C Garantia, Instructivo De Seguridad Y De Operaciones

Ocultar thumbs Ver también para Bitron 18C:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Malfunction Possible causes
Water is not
UVC bulb does not come on
clear
Cleaning rotor and quartz glass
sleeve are dirty
The pump capacity is not suitable
Flow rate through the Bitron is not
correct
The suspended material is brown
and sinks to the floor of the pond.
The pond is extremely dirty and full
of fish food
Fish stock and animal stock is too
high
Light has no UVC capacity
Bypass setting is not correctly
adjusted.
No water is
The inserted flow nozzle is very
discharged at
dirty
one or both of
One or both water discharges
the water
(bypass, UVC) are very dirty
discharges

15. Parts subject to wear

(Fig. 6)
1
UVC bulb 18 W
3
UVC bulb 36 W
4
UVC bulb 55 W
5
Cleaning rotor 18C
6
Cleaning rotor 36C/55C
English
Measures
Check electrical connections
See chapter 10 cleaning
See chapter 7, Installation
See chapter 7, Installation
Remove algae and leaves and improve the
mechanical filtration via Biotec. Prevent
sources of debris (falling leaves for instance).
Check the water values and replace some
of the water as needed. Use the Biotec.
The following applies as a guide value:
max. 1 kg (2.2 lbs) fish for 1.000 l (265 Gal)
pond water.
The bulb should be replaced after 8000
operating hours.
Select the correct setting for the pump
used. If the setting is correct: set the next
higher step (pump capacity).
1. Unplug the Bitron's power plug.
2. Disconnect the pump.
3. Unscrew the hose adapter, remove the
flow nozzle and clean it.
4. Clean water discharges (bypass, UVC);
also from the inside as needed.
ID no. 56236
ID no. 55432
ID no. 56636
ID no. 35068
ID no. 35069
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bitron 36cBitron 55c

Tabla de contenido