G G
B B
LED SIGNALS
DL1 -
(Yellow) - Signals the presence of secondary voltage (12VDC)
DL2 -
(Red) - Indicator for the storage of times and Codes of the
radio-transmitter.
DL3 -
(Red) - Gate closing CLOSE M1
DL4 -
(Green) - Gate opening OPEN M1
DL5 -
(Red) - Gate closing CLOSE M2
DL6 -
(Green) - Gate opening OPEN M2
- B -
ADJUSTING THE MICROSWITCHES
DIP 1
CHECK THE ROTATION DIRECTION OF THE
MOTOR (POINT C)
DIP 2
PROGRAMMING TIMES (POINT D)
OPERATING MICRO-SWITCHES
DIP 3
Photocells always active (OFF) - Photocells active only when
closing (ON)
DIP 4
Pre-blinking (ON)
DIP 5
Pause time before the automatic closing (ON)
DIP 6
Facilitation for the electric lock release system (ON)
S2
Functioning selection for 1 or 2 motors. If you want the
functioning just for one motor, cut the trace.
RESET
Every time you change the position of the dips (excepting DIP 1 and 2),
connect the RESET jumper for at least 1 second (this procedure can also
be carried out using a screw driver).
The RESET you carried out is shown by the simultaneous activation of
the blinker.
- C -
CHECKING THE ROTATION DIRECTION OF THE
MOTOR
This check is intended to facilitate the installer when fitting the system or
at any possible future control.
1 - Release the motor and move the gate to half open position;
2 - Put Dip 1 in the On mode => the LED DL2 starts blinking;
3 - Press the PROG button and hold it (the gate now is controlled in a
dead man mode: open, stop, close, stop, open) => THE RED LED
DL3 and the DL5 "CLOSE" come on and the gate starts closing. The
second leave closes two seconds after the first one. If this does not
happen, invert the wires of the motors V1,W1 and V2, W2);
4 - Press the PROG button and hold it => THE GREEN LED DL4 and
the DL6 "OPEN" come on and the gate starts opening. The two gate
leaves will open with a two second difference;
5 - Adjust the mechanical stoppers in opening;
6 - Press the hold the PROG button until both gate leaves reach the
completely close position and are now ready for the "Timing
programming";
7 - Set the electrical limit switches if provided;
8 - When the check is finished, position DIP 1 back on mode OFF =>
The LED DL2 turns off, signalling the exit from the checking mode.
NB: During this checking procedure, safety strips and ´fotocosta´
units are not activated.
ELECTRIC TORQUE-ADJUSTER
The torque is adjusted by rotating the TORQUE trimmer.
If you rotate it clockwise, more torque is applied to the motor.
So to give the max. pickup to the motor when it starts, torque adjusted
with the trimmer is
automatically applied just 3 seconds after the beginning of every
operating cycle.
- D -
PROGRAMMING TIMES
The programming must be carried out when the gate is closed.
1 - Position the DIP 2 on mode ON => The LED DL2 emits some short
blinkings
2 - Press button PROG. => The leaf M1 opens.
3 - At the end of the opening cycle, wait 2 seconds and then press button
PROG. to open the leaf M2.
4 - At the end of the opening cycle, wait 2 seconds and then press button
PROG. to start the count of pause times before the automatic closing.
(you can set it as you want, with max. 5 minutes - excluded by DIP 5
on mode OFF)
5 - Press button PROG. to command the closing of the leaf M2.
6 - Press button PROG. again to command the closing of the leaf M1 and
then determine the phase difference of the leaves (the LED DL2 turns
off). When the gate is closed, the procedure is terminated.
7 - AT THE END OF THE PROGRAMMING, POSITION THE DIP 2 ON
MODE OFF AGAIN.
F
UNCTIONING OF OPERATING ACCESSORIES
JOGGING OPERATION BUTTON (COM - K BUTTON - with timer
function)
It cyclically gives the commands open-stop-close-stop-open-etc.
TIMER FUNCTION
This function can be useful in rush hours, when vehicle traffic is slow (e.g.
entry/exit of workers, emergencies in residential or parking areas, and,
temporary, for removals).
APPLICATION MODES
If you connect a switch and/or a daily/weekly timer (at place or in parallel
to the opening button N.O. "COM-K"), you can open the automation and
keep it open as long as the switch is operated or the clock is activated.
When the automation is open, all operating functions are inhibited.
If the automatic closing is selected, the automation immediately closes
when the switch is released or at the time previously set; If not, you need
to use a command.
RADIO TRANSMITTER
It cyclically gives the commands open-stop-close-stop-open-etc.
AUTOMATIC CLOSING
Pause times before the gate automatically closes are stored during the
programming
procedure for the times.
The maximum pause time is 5 minutes.
The minimum pause time can be enabled or disabled using DIP5 (ON
enables).
FACILITATION FOR THE ELECTRIC LOCK RELEASE SYSTEM
DIP 6 ON => Enabled (not carried out in systems with electric limit
switches)
When the opening impulse is given, the lock is activated and the motor/s
first close/s for 1 second, then stop/s for half a second and eventually
start/s again in the opening mode.
OPERATION AFTER BLACK-OUT
When mains electrical power is restored press the opening button (K,
OPEN, radio).
The gate will open. Let the gate close itself with automatic closure or wait
that the flasher stops blink first to command the closing movement. This
operation is valid to obtain the leaves position readjustment. During this
phase all safety devices are active.