RIB KIT KING Manual Del Usuario página 28

Ocultar thumbs Ver también para KIT KING:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
C
ANCELLATION OF ALL RADIO CODES ENTERED
LED on
2s
2s
Press S1 briefly
LED L1 (Red) SIGNALS
1 Blinking*
= Signal not valid
1 Flash**
= Stored code or gate according to the procedure
you chose.
2 Blinkings
= Code already present
2 Flashes
= Overlaid radio signals during the storage
3 Blinkings
= Saturated memory (max. 59 codes)
3 Flashes
= Empty memory, no codes memorized.
4 Blinkings
= End of available time for the storage or the
cancellation of a single code.
4 Flashes
= You want to cancel a code that was not stored in
the memory
* Blinking: the LED is turned of for 0.50 seconds
**Flash: the LED is turned on for 0.25 seconds
ATTENTION! The receiver learns, along with the code, also the
channel you want to use. Therefore remember the
button of the radio transmitter you press during the
code learning procedure, because that very button
will activate the system.
LED off
2s
No cancel confirmation
2° 3°
3 flashes = memory
empty confirmation
T
ECHNICAL FEATURES
Humidity
Power supply voltage
Frequency
Transient main power drops
Max. power managed at the motor output
Max. load at the blinker output
Max. card power absorption (excluding the accessories)
Current available for the photocells
Protection degree
Weight of the equipment
Dimensions
T
ECHNICAL FEATURES OF THE RADIO
Frequency for the reception
Impedance
Sensitivity
Energizing time
De-energizing time
Current available on the radio connector
- All inputs shall be used as clean contacts without earthing, because
the power supply is generated in the card and is structured in such a
way to guarantee the respect of double and reinforced insulation to
the elements under voltage
- All inputs are managed by a programmed circuit that carries out a
self-control every time the gate is operated.
RELAY
K1 - Power relay enabling the blinker
K2 - Power relay enabling the opening M1
K3 - Power relay enabling the closing M1
K4 - Power relay enabling the clutch M1
K5 - Power relay enabling the opening M2
K6 - Power relay enabling the closing M2
K7 - Power relay enabling the clutch M2
K8 - Power relay to enable the electric lock
<95% without
condensation
230V±10% (on request
120V/60Hz)
50/60Hz
20ms
1CV
40W with resistive load
50mA
0.4A±15% 12Vdc
IP54
0.80kg
14.7 x 6 x 18cm
433.92MHz
52
>2,24 V
300ms
300ms
200mA 12Vdc

Publicidad