motormatic CT-200 Manual De Instrucciones página 32

Tabla de contenido

Publicidad

GB
TAB.2
N.
Function
OFF ON
Desciption
Dip
1
Open - Stop - Close
2
1
Open - Close
Step-by-step input
2
and radio channel
1
Open
mode
Condominium function
2
1
Open – Close
(Cut out of opening control)
2
3
J1=Open pushbutton
J2=Close pushbutton
4
3
J1=Thermostat
J2=Photocell 3
4
Jolly input mode
3
2
nd
pair of limit switches
J1=FCA J2=FCC
4
3
J1=Clock
J2=Photocell 3
4
Cut out
Pre-flashing light
5
Connected
Cut out
Re-closure
6
Connected
Cut out
Photo test
7
Connected
Cut out
Release thrust
8
Connected
Cut out
Slowdown
9
Connected
Cut out
Closing thrust
10
Connected
Control unit for 1
motor or 2 in
parallel
Mode
11
Control unit for 2
independent
motors
Incorp. radio
12
Notes
During opening, upon pressing the P/P button the gate stops, pres-
sing it again the gate closes. During closing, upon pressing the P/P
button the gate stops, pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops for a
few seconds and then closes. During closing, upon pressing the P/P
button the gate stops for a few seconds and then opens.
During opening, pressing the P/P button has no effect. During the pause,
pressing the P/P button has no effect. During closing, upon pressing the
P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/P button has no effect. During the pause,
upon pressing the P/P button the gate closes. During closing, upon pres-
sing the P/P button the gate stops for a few seconds and then opens.
J1 = opening pushbutton
J2 = closing pushbutton
Use NO contacts or pushbuttons
J1=Ambient thermostat for compensating working times (optional). Open
contact=normal times, closed contact=longer times.
J2=Input for third photocell; it only activates during opening and forces closing.
Use a NC contact.
For installations where 4 limit switches (gate stops) are mounted. Connect the
motor M1 limit switches to the inputs FCC and FCA. Connect the motor M2 limit
switches to the inputs J1 and J2. Use NC contacts.
J1=Clock input; this closes the gate when the contact is opened and opens it when
the contact is closed. J2=input for the third photocell; it only activates during ope-
ning and forces closing. Use NC contacts.
The flashing light is powered at the same time as the motor.
The flashing light is powered 5 seconds before any movement.
After one complete opening, the control unit only closes again with
a manual control.
After one complete opening, the control unit closes automatically
after the programmed pause time.
See text in Fototest section.
See text in Fototest section.
Function cut out.
The release thrust has the function of releasing the electric lock. The leaf with M1
gives a short thrust in the closing direction before starting to open.
There is no slowdown in the last part of travel.
With the slowdown function connected, the motor halves its speed
towards the end of every gate movement.
No closing thrust is carried out.
The control unit ends gate closure with a short full-power thrust on
motor M1.
The outputs M1 and M2 work in parallel and the pedestrian control
partially opens/closes the gate leaf/s. For single motor control, see
the section "Programming the times".
The outputs M1 and M2 are independent and the pedestrian con-
trol fully opens and closes the leaf with motor M1. For motor con-
trol, see the section "Programming the times".
When the incorporated receiver is NOT used, it MUST be cut out.
Incorporated receiver enabled.
31
E
Tipología 1
AUTOMATIZACION DE 2 MOTORES SIN FINALES DE CARRERA ELECTRICOS
Programación:
1 - Cortar el suministro de corriente a la central.
2 - Desplazar la cancela hasta la mitad de recorrido.
3 - Presionar la tecla STOP/PROG. (n° 19 de la fig. 1).
4, 5 y 6 - Dar alimentación a la central, manteniendo presionada la tecla STOP/PROG. hasta que se encien-
da el led L1 (n° 3 de la fig. 1).
7 - Pulsar el botón P/P (n° 18 de la fig. 1): se pone en marcha, en fase de cierre, el motor M2 (hoja sin elec-
trocerradura). (Si el motor gira al contrario, hay que cortar el suministro de corriente, invertir las fases
del motor y repetir el procedimiento).
8 y 9 - En cuanto haya llegado al tope, pulsar el botón P/P: el motor M2 se para y, automáticamente, se
pone en marcha, en fase de cierre, el motor M1 (hoja con electrocerradura).
10 y 11- Una vez que también M1 haya llegado al tope, pulsar el botón P/P: el motor se para y, automáti-
camente, se pone en marcha en fase de apertura.
12 - Durante esta maniobra, hay que escoger el tiempo de desfase en fase de apertura de las dos hojas.
Para configurar el tiempo de retardo, pulsar el botón P/P cuando la hoja con el motor M1 haya alcan-
zado el punto en que debería ponerse en marcha la hoja con el motor M2.