DMES−...
6. Press the gear coupling Z onto one of the clamping hubs.
7. With DMES−18: Insert the 4 screws into the holes in the coupling housing.
Press the clamping element (see Fig. 1) into the hole on the side of the coupl
ing housing. Fasten the coupling housing to the motor unit with the 4 screws
(torque see fig. 9). Fit the adapter again onto the DMES (torque 3 Nm).
8. With DMES−25...63:
Fit the coupling housing to the DMES
with four screws (torque see fig. 9).
Press the clamping element (see fig. 1)
into the hole on the side of the coupling
housing and push the two clamping
bodies apart.
9. Press the motor unit with correctly
placed coupling hub into the coupling
housing (if necessary turn the motor
unit).
10. Tighten the screw of the clamping element (torque see Fig. 9).
Fitting the product
Please note
S Please note that in the case of heavy loadings the axis must not be
Note that the IP protection class depends on the fitting position:
S
Vertical, diagonal or horizontal with cover band upwards: IP40
Diagonal or horizontal with cover band downwards: IP42
Use the grooves as shown in Fig. 10 for fastening the DMES.
S
Fig. 10
26
fastened only by the front cover.
Heavy tensile strain may cause the screws in the cover to be pulled out.
DMES−18
DMES−18: 1.2 Nm
DMES−25: 2.9 Nm
DMES−40: 5.9 Nm
DMES−63: 15 Nm
Fig. 9
DMES−40
DMES−25
DME−KG−18/25: 1.2 Nm
DME−KG−40/63: 9.9 Nm
DMES−
63
Festo DMES−... 0602a English