Welding parameters

Menu
Select program
Selection
Enter
Program: the display of the materials may vary according
to the machine and software versions.
Programs 1-3 are provided with preset parameters which can be adjusted during the welding process.
The adjustments are not saved!
The free settings 1-4 are preset in the factory and can be programmed freely. The parameters are saved even
after the device has been switched off.
Welding program
Free set 1 – 4
Prg1 PE-LD
Prg2 PE-HD
Prg3 PP
Prg0 PVC-U
The welding program (17) which is currently set can be seen in the workspace.
The display of the materials may vary according to the machine and software versions.
Setting the output volume
• Move the cursor to the «SPEED» position by pressing the Select key (28).
• Set the output value (30-100 %) by using the Up (29) or Down (27) key.
Setting the PLAST and AIR temperature
• Move the cursor to the «PLAST» or «AIR» position by pressing the Select key (28).
• Set the temperature value by using the Up (29) or Down (27) key.
Turning the device off
• Release drive locking device (4) and let go of the on/off switch for the drive (2)
Remove welding material in the welding shoe, so that the welding shoe will not be damaged the next time the
device is started up.
• Turn off the heating with the Standby/Enter key (26).
• Allow device to cool down for approx. 5 minutes.
• Turn off main switch (1).
Ideal PLAST [°C]
230
220
230
240
200
Free
setting
1-4
Ideal AIR [°C]
260
260
260
260
300
23