POINT A -
ELECTRIC CONNECTIONS
EXTERNAL MAINS POWER SUPPLY TO BOARD 230 Vac
50/60 Hz (120 Vac 60 Hz on request)
F
> PHASE
N
> NEUTRAL
> EARTH
F1
T1,6A FUSE ON MAIN POWER TERMINAL
J1
A-
COMMON WIRE OF ACCESSORIES POWER SUPPLY AND EDGE AUTO-
TEST
A+
POSITIVE FOR 24Vdc POWER SUPPLY TO ACCESSORIES
A+ TEST
POSITIVE FOR 24Vdc POWER SUPPLY TO EDGE AUTO-TEST
NEGATIVE FLASHER 24Vdc 20W
-
POSITIVE FLASHER 24Vdc 20W
+
SIGNAL
OPEN GATE INDICATOR 24 Vdc MAX 10 W
J2-J3
BATTERY
CONNECTORS FOR BATTERY CHARGER BOARD (CODE ACG4667
CHARGER
OPTIONAL)
J4
10V
CONNECTORS FOR SECONDARY 10 VAC TRANSFORMER
J5
BAT
BATTERY CONNECTORS (OPTIONAL)
J6
24V
CONNECTORS FOR SECONDARY 24 VAC TRANSFORMER
J7
SECURITY
CONNECTOR FOR MANUAL RELEASE SWITCH
LOCK
B – SETTINGS
DIP 1
adjust stroke in line with electrical or magnetic limit
switches (point C)
DIP 2
programme full opening (point D)
DIP 2-1
programme pedestrian opening times (point E)
DIP 1-2
save/delete radio codes for full opening control (point F)
DIP 1-2
save/delete radio codes for pedestrian opening control (point G)
CONTROL MICRO-SWITCHES
DIP 3
ON - gradual start enabled
OFF - gradual start disabled
DIP 4
ON - photocells enabled only when closing
OFF - photocells always enabled
DIP 5
ON - heater enabled
OFF - heater disabled
DIP 6
ON - radio, k butt button and pedestrian control enabled in automatic mode
OFF - radio, k butt button and pedestrian control enabled in step-by-step mode
DIP 7
ON - impact sensor enabled
OFF - Impact sensor disabled
DIP 8
ON - instant re-closing after transit on enabled photocell
OFF - instant re-closing after transit on disabled photocell
Trimmer TCA
J12
J11
J1
J8
LIMIT
SWITCH
J9
MOTOR
J10
X K800
J11
COM
STOP
PHOT
EDGE
CLOSE
OPEN
KBUT
B.I.O.
J12
ANTENNA TERMINALS DEDICATED TO CONNECTION OF A 433.92 MHz
DIP 9
ON - mode on always, even with remote control enabled
OFF - mode on always, even with control buttons enabled
DIP 10
ON - edge auto-test enabled
OFF - edge auto-test disabled
DIP 11
ON - pre-flashing enabled
OFF - pre-flashing disabled
DIP 12
OFF
ON
OFF
ON
DIP 14
ON - enable SUN/MOON radio system
OFF - enable SUN-PRO radio system
PROG.
MEMORY > EXTRACTIBLE MEMORY CONTAINING FUNCTIONAL DATA AND RADIO
SW
31
J10
Trimmer RUN
J2
J3
CONNECTOR FOR ELECTRICAL OR MAGNETIC LIMIT SWITCHES
CONNECTOR FOR 24Vdc MOTOR AND 5VDC ENCODER
CONNECTORS FOR MOTOR K800 CONNECTION (DO NOT USE)
CONTACTS COMMON WIRE (GND)
STOP PULSE CONTACT (NC)
PHOTOCELLS CONTACT (NC)
EDGE CONTACT (NC)
PED
PEDESTRIAN OPENING PULSE CONTACT (NO)
CLOSE PULSE CONTACT (NO)
OPEN PULSE CONTACT (NO)
SINGLE PULSE CONTACT (NO)
CONTACT (NO) DEDICATED TO A CLOCK
ANTENNA
DIP 13
IMPACT SENSOR SENSIBILITY (ACTIVE IF DIP 7 ON)
OFF
OFF
MEDIUM HIGH
ON
MEDIUM LOW
ON
> PROGRAMMING KEY.
CODES.
> CONNECTOR FOR SOFTWARE UPGRADE.
J9
J8
J7
J6
J5
J4
HIGH
LOW
G