DESCRIPTION OF CONTROL PANEL

Control panel for 24V d.c. gear motors, pow-
ered by 230V a.c. at 50-60 Hz (single-phase).
Designed to control FERNI and FROG
gear motors.
Designed and built entirely by CAME can-
celli automatici s.p.a., it meets regulations in
force and with IP 54 level of protection.
Housing in ABS equipped with vents to
provide internal air circulation. Guaranteed 24
months, unless tampered with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is protected
by a 3.15A-F fuse on the main power line.
Control systems are powered by low voltage
and protected by a 315mA-F fuse.
The total power consumption of 24V ac-
cessories (which are protected by a 2A-F fuse)
must not exceed 40 W.
-> Photocells can be connected to obtain:
• Re-opening during the closing cycle (2-
C1), if the photocells identify an obstacle
while the gate is closing, they will reverse
the direction of movement until the gate
is completely open;
• Partial stop (2-C3)
ing gate, with activation of an automatic
closing cycle;
• Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement).
-> The control board includes an amperometric
sensor for the motors which is activated when
an obstruction blocks the opening and closing
motions.
-4-

GENERAL CHARACTERISTICS

SAFETY
,
shutdown of mov-
The sensor's sensitivity can be adjusted
using the trimmers (see p. 26).
It normally inverts the direction of move-
ment, but if it activates when the gate is 5 cm
from being fully close or open, it completely
halts the movement (also see adjusting the OP
TIME trimmer page 28).
Warning! If an obstacle is detected two times in
a row during the closing phase (and when the Auto-
matic Closing function is on), the operator will:
1) it inverts the motion, completely opening
the gate;
2) it deactivates the Automatic Closing;
3) Block all functions of the control panel.
To reactivate the operator, send a "close com-
mand" by pushing the buttons connected on 2-3,
2-3P and 2-7 (only the button).
-> The transformers are equipped with a guard ,
which in case of thermal over load will keep the
doors open.
They are closed again only after the tem-
per a ture falls be low the overload thresh old.
ACCESSORIES WHICH CAN BE
CONNECTED TO THIS UNIT
-> "Gate open" signal light ;
-> Flashing signal light when gate is in motion
-> Cycle lamp
-> Electric lock ;
-> LB18 circuit card for emergency battery ,
which is automatically connected in case of
power failure; battery is recharged when line
power is restored
-> Radiofrequency AF board (see table page
30).