Installation
Warning
Interference due to electromagnetic sources is liable to
cause sudden compensatory movements of the axis.
Follow the installation procedure below in order to pre-
vent this electromagnetic interference.
Connect the earth connection on the left-hand side of
the housing with low impedance (short cable with
large cross-sectional area) to the earth potential, if the
axis interface is not attached to an earthed machinery
frame.
Only with measuring system type MLO-POT-...-LWG:
For earthing, connect the earth strip (included with the
measuring system) to the flat plug of the measuring
system and to the earthing connection of the axis in-
terface.
1
Measuring system
(here type
SPC-AIF-POT-LWG)
2
Earth strip (only
with measuring
system type
MLO-POT-...-LWG)
3
Earthing connection
16