Only with swivel module type DSMI-...:
For earthing, connect the earthing connection of the
DSMI and the earthing connection of the axis interface
using an earth strip or an earthing cable (cross-sec-
tional area at least 2.5 mm
1
Swivel module with
integrated measuring
system type DSMI-...
(rear view)
2
Earth strip or
earthing cable
3
Earthing connection
–
Do not lay any axis interface cables, CP cables,
measuring system cables or proportional directional
control valve cables near or parallel to cables with high
interference levels.
–
Use only original cables. Attach the plug with the help
of the union nut, so as to avoid any unintentional
slackening caused by oscillation etc.
–
Seal any unused connectors with the protective caps
provided. Only then is the IP65 type of protection en-
sured.