fitting the end limit brackets
[1]
Manually move the gate to the open position.
[2]
Position a bracket onto the rack so that it activates the motor end limit contact.
[3]
Screw the bracket onto the rack.
[4]
Manually move the gate to the closed position then repeat steps 2 and 3 to fit
the second bracket to the rack.

Wiring

General wiring diagram

terminals
description
1
N
2
L
3-4-5
1-4
7
COM
8
START
9
STOP
10
PHOT
11
SWO
12
SWC
13-14
0V-24V~
15-16
17
ANT
18
ANT
19
COM
20
PED
aerial wiring
For optimum reception, the aerial must not be cut and must be as far away
as possible from the power supply terminal blocks and wires. The aerial
must always be installed at a height and must be visible from a distance.
Do not fit the aerial to a metal post or behind a wire fence.
Cut the coaxial cable if it is too long. Shortening the cable will improve the
signal (a coaxial cable which is too long, extended or connected with an
insulating screw joint will distort the signal).
The mounting plate is an active component of the aerial. It must not be
removed or modified.

Connection to the power supply

To connect the motor to the power supply, use a standard multicore cable with a minimum
cross section of 3x1.5mm².
Inputs 9 and 10 must be bridged to terminal 7 if they are not used to connect a
safety device.
6
function
Neutral single-phase 230 V~, 50-60 Hz power supply
Live single-phase 230 V~, 50-60 Hz power supply
Motor connection (4 = shared, 3 and 5 = motor and capacitor)
230 V output, flashing orange light
Shared by control inputs (8-9-10-11-12)
Control point input, sequential operation
Control point input (closing only)
Photoelectric cell input
Opening end limit contact
Closing end limit contact
Alternating 24 V output for power supply to the additional devices
Unused outputs
Aerial core
Aerial braid
Shared
Pedestrian opening control point input
SX
5 mm
a
b
15 mm
Copyright © 2008 Somfy SAS. All rights reserved.
DX
a
b

Publicidad