General Characteristics - CAME Z Serie Manual De Usuario

Ocultar thumbs Ver también para Z Serie:
Tabla de contenido

Publicidad

Description
The ZL150N control panel is suitable for con-
trolling automatic systems for the FLEX series
swing gates powered by 24V d.c. with capacity
up to 48 W.
Designed and built entirely by CAME S.p.A. to
meet safety standards at an IP 54 protection
level. Housing in ABS.
Guaranteed 24 months, unless tampered with.
The circuit requires 230V (a.c.) at terminal
blocks L1-L2 and the inlet is protected with 1,6A
fuse. The command devices are low voltage and
protected by a 1.6A fuse, whereas the
gearmotor and electric lock are protected by
5A fuses.
The accessories' total wattage (24V) must not
exceed 40W.
Safety
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if the pho-
tocells identify an obstacle while the gate is
closing, they will reverse the direction of move-
ment until the gate is completely open;
- Re-closing during opening (2-CX, dip 8OFF-
10OFF), if the photocells identify an obstacle
while the gate is opening, they will reverse the
direction of movement until the gate is com-
pletely closed;
- Partial stop, shutdown of moving gate, with
activation of an automatic closing cycle (2-CX,
dip 8OFF-10ON);
- Total stop (1-2), shutdown of gate movement
without automatic closing; a pushbutton or ra-
dio remote control must be actuated to resume
movement.
NB: If an NC safety contact (2-C1, 2-CX, 1-2)
is opened, the LED will flash to indicate this
fact.
Optional accessories
- Gate open pilot lamp (3W) . A lamp that sig-
nals the gate's open position and that goes out
when the gate is in the closed position. Con-
nected to terminals 10-5.
- Electric lock (2-S);
- LB54 Board . Powers the reduction gears
through batteries in case of a power outage.
After the power supply is restored, it also re-
charges the batteries.

GENERAL CHARACTERISTICS

Other functions
- Automatic closing. The automatic closing timer
is automatically activated at the end of the open-
ing cycle. The preset, adjustable automatic
closing time is automatically interrupted by the
activation of any safety system, and is deacti-
vated after a STOP command or in case of
power failure;
- Obstacle presence detection: When the mo-
tor is stopped (gate is closed, open or half-open
after an emergency stop command), the trans-
mitter and the control pushbutton will be deac-
tivated if an obstacle is detected by one of the
safety devices (for example, the photocells);
- Hammer movement. At every opening com-
mand, the wings press the closing stop-ledge
for a second, thus facilitating the release op-
eration of the electric lock connected to termi-
nals 2-S.
It is only active if the wings are closed and at
the end of the work time or at the 1
vre after the system has been powered;
- "Operator present" function: Gate operates
only when the pushbutton is held down (the
radio remote control system is deactivated);
- Partial opening , second motor door opening,
adjusted with TR2M trimmer; it is activated by
collecting to the terminals 2-3P;
- Pre-flashing for 5 seconds, while the door is
opening and closing;
- Type of command:
-open-stop-close-stop for pushbutton and ra-
dio transmitter;
- open-close-reverse for pushbutton and radio
transmitter;
-open only for radio transmitter.
Adjustments
- Automatic closure time;
- Partial opening time and delay in closing of
the M2 motor;
- Operating time.
Important! Disconnect the unit from
the main power lines before carrying out
any operation inside the unit.