MAINTENANCE AND CLEANING

• If necessary, clean with clear water using a soft
brush.
• Do not use cleaning agents or chemical solutions.
We recommend using OASE PumpClean for remov-
ing calcium deposits.
• Cleaning and replacement cycles for filter media are
dependent on the size of the aquarium and the
number of fish. Therefore, it is necessary to clean
and replace the filter media as required to ensure
optimum filter performance.
• If there are several foam filters: Clean or replace the
foam filters at different times. This saves enough
useful bacteria to ensure good biological filtration
of the water.
Cleaning/replacing the filter media
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to remove
any soiling. (→ Cleaning/replacing the filter media)
 O
Filter media
FiltoSmart
FiltoSmart Thermo
a
Foam filter 10 ppi
b
Foam filter 20 ppi
c
Ceramic substrate
(420 g bag)
d
Activated carbon
e
Foam filter 10 ppi
Prerequisite
• The unit head is removed. (→ Dismantling the unit
head)
How to proceed:
 P
• Remove the foam filters and rinse in warm water or
replace.
• Position the foam filters and activated carbon. The
activated carbon has to be taken out of the plastic
packaging but remains in its filter bag.
• Rinse the ceramic substrate in warm water or re-
place.
– FiltoSmart 300 requires three, FiltoSmart 200
two and FiltoSmart 100 one bag (420 g) of ce-
ramic substrate.
Cleaning the heater unit
The following applies to all units with heater:
• Adhere to the rules for careful handling. (→ Careful
 D, E
• Unscrew the holding ring and clean the heater ac-
• Reassemble the unit in the reverse order.
Cleaning/replacing the impeller unit
Prerequisite
• The unit head is removed. (→ Dismantling the unit
Quantity
100
200
300
 R
1
1
1
• Pull the pump lid off downward.
1
1
1
2
3
• Remove the impeller unit, clean or replace.
• Reassemble the unit in the reverse order.
2
2
1
1
Re-installing the unit
• Reassemble the unit head and filter unit. (→ Fitting

WEAR PARTS

The following components are wear parts and are ex-
cluded from the warranty:
• Suction cups
• Impeller unit
• Foam filters
• Activated carbon
• Ceramic substrate
– Before using for the first time, remove the ce-
ramic substrate from the plastic bag, rinse it in
warm water and put it loosely into the filter con-
tainer.
– Cover the heater tube, if applicable, when adding
the ceramic substrate to ensure that no substrate
can enter the heater tube.
N O T E
handling of the heater)
cording to the separately provided manual or, to re-
place it, pull it out of the holding ring.
head)
– FiltoSmart 200/300: Push the tab down.
– Ensure that the two rubber bearings are correctly
seated.
– Ensure that the vent hose is in place and is point-
ing upwards so that the air can escape.
the unit head)
- EN -
23