Compatible StickFix abrasives are quick and
easy to attach to the interface pad.
► Press the abrasive [6-1] onto the interface
pad [6-2].
6-1
8.3
Changing the interface pad [7]
CAUTION
Decreasing StickFix coating adhesion
Risk of injury from flying parts
► Check the StickFix coating on the interface
pad and the abrasive regularly for wear.
► Replace interface pad/abrasive with worn
StickFix coating.
The interface pad is attached to the backing pad
with eight screws.
► Remove the abrasive.
Loosen screws by turning the screwhead
or a coin (e.g. a euro) anticlockwise.
Remove the interface pad [7-1].
Vacuum the backing pad and clean with
a brush if necessary.
Place a new interface pad on the backing
pad.
Insert all eight screws one after the oth­
er.
The interface pad is optimally aligned.
Tighten all screws clockwise in a
crosswise sequence.