PUMP SUNTEC J TECHNICAL DATA
PUMP
IDENTIFICATION
(Not all model combinations are available.
Consult your Suntec representative)
J : Pressure regulation
(see pump capacity curves)
(seen from shaft end)
A : clockwise rotation/
right hand nozzle.
B : clockwise rotation/
left hand nozzle.
C : anti clockwise rotation/
left hand nozzle.
D : anti clockwise rotation/
right hand nozzle.
J
6
C
A
C 1 001
Flange mounting
000 : conical connection threads
cut-off function
001 : cylindrical connection threads
cut-off function
002 : cylindrical connection threads
by-pass nozzle, no cut-off function
Revision number
5 : for J4 and J6
4 : for J7
Installation
P : by-pass plug installed in return port
for two-pipe operation
General
Mounting
Flange mounting according to EN 225.
Model 1000
Connection threads
Conical
Inlet and return
1/4"NPTF
Nozzle outlet
1/8"NPTF
Pressure gauge port
1/8"NPSF
Vacuum gauge port
1/4"NPTF
Valve function
Pressure regulating and cut-off (except for 1002 models).
Strainer
Open area : 45 cm
Opening size : 170 μm
Shaft
Ø 11mm according to EN 225.
By-pass plug
Inserted in return port for 2 pipe system;
to be removed with a 3/16" Allen key for 1 pipe system.
Weight
4 kg
Hydraulic data
Nozzle pressure range
C : 10 - 21 bars
E : 10 - 30 bars
Delivery pressure setting 12 bars
Operating viscosity
2 - 75 mm²/s (cSt)
Oil temperature
0 - 90°C in the pump.
Inlet pressure
1,5 bars max.
Return pressure
1,5 bars max.
Suction height
0,45 bars max. vacuum to prevent air separation from oil.
Rated speed
3600 rpm max.
Torque (@ 45 rpm)
0,30 N.m
Oil under suction
Gear set capacity
Oil under pressure
By-passed oil
Filter
returned to tank,
or to suction
Shaft rotation
and nozzle location
Pressure range
C : 10-21 bars
E : 10-30 bars
5 P
Models 1001/1002
Cylindrical (according to ISO 228/1)
G 1/2
G 1/4
G 1/8
G 1/2
²
15
420010329701 Maior P 300.1/400.1 AB
Back
to suction
Return
plugged
Inlet
Gear set
Pressure
adjustment
Pressure
By-pass
gauge port
plug
inserted
TWO PIPE
INSTALLATION
Return
Pump capacity
Capacity (L/h)
400
J 7
300
J 6
200
J 4
100
0
5
10
15
20
25
Viscosity = 5 cSt - rated speed = 2850 rpm
Data shown take into account a wear margin.
Do not oversize the pump when selecting the
gear capacity.
By-pass
plug
removed
ONE PIPE
INSTALLATION
Vacuum
gauge port
To nozzle
30
35
Pressure (bars)