Gima CORSIA Manual De Istrucciones página 17

Ocultar thumbs Ver también para CORSIA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC
DIRECTIVE 2012/19/UE-WEEE:
The symbol on the device indicates the separated collection of electric and electronic equipment. At the end of
life of the device, don't dispose it as mixed solid municipal waste, but dispose it referring to a specific
collection centre located in your area or returning it to the distributor, when buying a new device of the
sample type to be used with the same functions. This procedure of separated collection of electric and
electronic devices is carried out forecasting a European environmental policy aiming at safeguarding,
protecting and improving environment quality, as well as avoiding potential effects on human health due to
the presence of hazardous substances in such equipment or to an improper use of the same or of parts of the
same Caution: The wrong disposal of electric and electronic equipment may involve sanctions.
The CORSIA atomiser does not need maintenance or lubrication.
Before use always check correct functioning and safety of the device. Carry out disinfection as described in the "CLEANING ACCESSORIES"
section. Unpack the instrument and always check integrity of plastic parts and feeding cable, they might have been damaged during previous use.
Connect cable to electrical network and turn switch on.
Close the air outlet with one finger to make sure that noise produced is regular and there is no malfunctioning.
With the air outlet always closed check the correct functioning of the nebulization regulator by turning the knob form MIN to MAX. Make sure the
indicator of the pressure meter is working correctly.
Verify that the atomiser is not damaged by previous use (it was badly put away or badly knocked).
A protection fuse (F 1x1.6A L 250V) reachable from exterior and it situated in the plug protects the instrument. For use replacing, always check the
type and the range indicated.
The manufacturer will provide upon request electric diagrams, components list, description, setting instructions and any other information
that can help the technical assistance staff for product repair.
Fault type
1. The device doesn't work
2. Low Nebulization
3. Low Nebulization
4. Absence of Nebulization
5. Slow Nebulization
6. Noisy Device
Fault 1 - 2 - 3 - 4 - 5 - 6
If the unit doesn't nebulizer once the above conditions have been checked, we suggest to contact your dealer or technical service GIMA SpA.
BEFORE EVERY CHECKING OPERATION, IN CASE OF ANOMALIES OR BAD FUNCTIONING, PLEASE CONTACT GIMA TECHNICAL SERVICE.
GIMA SpA DOES NOT GIVE GUARANTEE IF INSTRUMENT, AFTER THE TECHNICL SERVICE CHECKING, APPEARS TO BE TAMPERED.
ANY MINIMAL MODIFICATION / REPAIR ON THE DEVICE VOIDS THE WARRANTY AND DOES NOT GUARANTEE THE COMPLIANCE WITH THE
TECHNICAL REQUIREMENTS PROVIDED BY THE MDD 93/42/EEC DIRECTIVE (AND SUBSEQUENT CHANGES) AND ITS NORMATIVES.
MAINTENANCE
Cause
a) The plug may be misplaced in the
wall socket
b) Thermal protector may be on (the
device has been working beyond its
limits and / or near heat sources)
Clogged Nebulizer Tank
Clogged Nebulizer Tank
Clogged Nebulizer Tank
Highly dense drug
Extended use
No solution with previous items
a)
Make sure the plug is properly placed in the wall
socket. Make sure the ON/OFF switch is in
position I.
b)
Switch off the device by pressing the switch to
position 0 and left the motor cool down for at
least 30 minutes.
Clean and disinfect the nebulizer tank as explained in
If cleaning was not succesful change cruet
Check that the nebulizer contains medication; Make
sure that the nebulizer is not clogged;
Check the connection between the compressor air
outlet port and the accessories
Dilute drug in physiological liquid
Call retainer or Technical service GIMA SpA
Call retainer or Technical service GIMA SpA