Transport, Storage And Disposal - Madas M16/RM N.C. EEX Manual Del Usario

Ocultar thumbs Ver también para M16/RM N.C. EEX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.0 - CPI SWITCH
If the solenoid valve comes with CPI, the position of the micro switch is already calibrated and
set, therefore, for operation you simply need to connect it to the power supply.
If CPI calibration adjustments are required, it is possible to act on the 2 screws (17) and 2
nuts (18) so that with the valve closed, the CPI provides the desired signal.
7.1 - TECHNICAL DATA and CPI SWITCH WIRING (see figure on the side)
Refer to the attached technical manual regarding CPI.

8.0 - TRANSPORT, STORAGE AND DISPOSAL

• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (e.g. painting, cataphoresis, etc), it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery, it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product is to be disposed of separately from other waste (WEEE directive 2012/19/EU)
and in compliance with the legislation in force in the country where this operation is performed.
9.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described herein;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, other manufacturers's assembling units, making changes to the device and
natural wear.
10.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
• CE-51AT1438
• Cl. A
• Gr. 2
• EN 161
• P.max or PS max
• IP....
• 220-240V....
• (-20...+50) °C
(if it is present) = In compliance with PED directive followed by the no. of the Notified Body
• year
• Lot
• U1812
• 7634
• 00001
M16/RM N.C. EEX
= device name/model followed
by the connection diameter
= certification pin number
= Seal strength in counterflow at 150 mbar in accordance with EN 161
= Mechanical resistance group 2 in accordance with EN 161
= Product reference regulation
= Maximum pressure at which product operation is guaranteed
= Protection rating
= Power supply voltage, frequency (if Vac), followed by electrical absorption
= Temperature range within which product operation is guaranteed
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
= In compliance with ATEX followed by the protection mode
= Year of manufacture
= Product serial number (see explanation below)
= Lot issued in year 2018 in the 12th week
= progressive job order number for the indicated year
= progressive number referring to the quantity of the lot
= Disposal in accordance with WEEE directive 2012/19/EU
Mod.: M16/RM N.C. DN 40 EEX
CE-51AT1438 CI.A Gr.2 EN 161
IP65 - 220-240 V/50-60 Hz 7,7-9,4 VA (-20...+50) °C
year: 2018
14
Madas Technical Manual - 2|2.2a - REV. 0 of 10
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
PS max:6 bar
II 2G
0051
II 2D
0497
Lot:U1812
7634/00001
May 2018
th

Publicidad

Tabla de contenido
loading

Tabla de contenido