GENERAL INSTRUCTIONS
Apart from the corner models, the"Young Collection" Jacuzzi
whirlpool baths are available with the backrest either on the
left or right hand side. The Left-Right version may be identified
by standing in front of the bath facing the control panel.
Jacuzzi Europe recommends the use of the removable front
panel, available on request, which allows access for any neces-
sary maintenance operations. On request, side panels for one
or both of the short sides of the "rectangular models" can be
supplied.
In the corner models, a gap about 50 cm wide should left
along the entire external border of the bath to allow the
assembly and removal of the panels. For fitted baths, or those
with the control panel facing the wall, access needs to be pro-
vided for maintenance to the electrical pump, the electric box
and the area below the control panel. This access space can be
closed with removable panels at least 45 cm high measured
from the floor (see information sheet, ref. 6).
Furthermore, adequate ventilation must be available for the
bath unit, with vents between the bath covers and the remov-
able panels, well distributed and non-obstructed.
The baths can be installed against tiled walls and on a tiled
floor because the space available between the bottom of the
bath and the floor is sufficient to allow the assembly of ade-
quately sized siphons/siphon boxes. Make sure that the floor
drainage hole (ref. 1) is correctly positioned (height Y) for the
bath drain, shown in the information sheet, according to the
type of siphon to be used (not supplied).
All models need to have the electrical box, fixed to the frame
(ref. 2), connected to the electrical supply and correctly
earthed. The cable may follow various routes as long as there
are no improvised connections. In all cases, refer to the "Elec-
trical safety" chapter.
HOT/COLD WATER SUPPLY
The water can be supplied from an external tank unit with a
wall outlet (minimum length X), positioned at references 3 or
3a indicated in the information sheet. On some models posi-
tion 3b can only be used when the drain is against the wall.
The "Young Collection" Jacuzzi
waste pipe fitted with a water spout. In this case it is possible to
use two fitted taps or a single control tap, with the water sup-
ply coming from the waste pipe with the water supply spout.
The water pipe ( copper, 14 mm ø) for the mixed water can
come up from the floor, in the position indicated by the sym-
*
bol
in the diagram (ref. 4).
There are alternative positions for connecting the pipe (see 4a).
Please note that the pipe must reach the upper part of the
drainage column.
If a bath unit is used without a shower diverter, it will be nec-
essary to fit a diverter after the taps to allow the future instal-
lation of a shower head.
baths are also available with a
™
ELECTRICAL SAFETY
™
"Young Collection" Jacuzzi
ances constructed to comply with the EN 60335.2.60 regula-
tions and are approved by the Italian Quality Trademark Insti-
tute (IMQ) and other European institutes. All the products are
tested during production to guarantee the customer's safety.
The installation must be carried out by qualified persons who
must be able to guarantee compliance with the current
national regulations and who must also be authorised to issue
the confirmation that the installation has been carried out cor-
rectly.
IT IS THE INSTALLER'S RESPONSABILITY TO SELECT MATERIALS
IN RELATION TO EXPECTED USE; TO PERFORM THE INSTALLATION
CORRECTLY AND TO CHECK THE CONDITION OF THE SYSTEM TO
WHICH THE WHIRLPOOL BATH IS TO BE CONNECTED, IN ORDER
TO FIND OUT WHETHER IT CAN ENSURE SAFE USE.
"Young Collection" Jacuzzi
appliances and must therefore be securely located and con-
nected in a permanent manner, without intermediate junc-
tions, to the electrical supply and the protection system (earth-
ing plant).
THE ELECTRICAL AND EARTHING PLANT FOR THE APPLIANCE
MUST BE EFFICIENT AND IN CONFORMITY WITH THE LEGAL
REQUIREMENTS AND THE SPECIFIC NATIONAL REGULATIONS.
The connection to the electricity supply requires the installation
of an omnipolar isolation switch which must be located in a
suitable position to ensure that the bathroom safety regulations
are respected. This omnipolar switch must guarantee that the
contacts remain open at least 3 mm and be suitable for voltages
of 220-240 V and a current of up to 16 A.
IN ACCORDANCE WITH THE REGULATIONS, THE SWITCH AND
OTHER ELECTRICAL DEVICES MUST BE LOCATED IN AN AREA
WHICH CANNOT BE REACHED BY THE PERSON WHO IS IN THE
WHIRLPOOL BATH.
The installation of electrical devices and other equipment
(sockets, switches, etc.) in the bathroom must be in strict
accordance with the legal requirements and regulations for
each country. In particular, no electrical installations are to be
made within the area surrounding the whirlpool bath in a
range of 60 cm horizontally and 225 cm vertically.
The connection to the electrical plant mounted in the bath unit
must be made with a sheathed cable having characteristics not
less than H 05 VV-F 3x2.5 mm
"YOUNG COLLECTION" JACUZZI
CONNECTED TO AN ELECTRICAL SUPPLY FITTED WITH A 0.03A
DIFFERENTIAL SWITCH.
"Young Collection" Jacuzzi
terminal, located near the pump and labelled with the symbol
, for the equipotential connection of the surrounding metal
components, as required by regulations EN 60335.2.60.
™
whirlpool baths are safe appli-
™
whirlpool baths are class "I"
2
.
™
WHIRLPOOL BATHS MUST BE
™
whirlpool baths are fitted with a