Transport, Storage And Disposal - Madas EVPF/NC Manual Del Usuario

Ocultar thumbs Ver también para EVPF/NC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.2 - CPI SWITCH WIRING
• Before wiring the CPI connector (29), fully unscrew and remove the central screw (31);
• Connect the CPI connector (29) terminals 1 and 2 in series to the signalling device (see diagram 2 - fig. 5).
Use the proper cable terminals (see figures in 3.2);
• Wire the CPI connector (29) with a 3x0.75mm² cable with an external Ø measuring 6.2 to 8.1 mm. The cable must be in
double sheath, suitable for outdoor use, with a minimum voltage of 500V and a temperature of at least 90°C;
• Secure the CPI connector (29) by tightening (recommended tightening torque 0.4 N.m ± 10%) the centre screw (31);
• Open and close the solenoid valve (by supplying and cutting off the power) 2-3 times to make sure the microswitch is
signalling correctly.

7.0 - TRANSPORT, STORAGE AND DISPOSAL

• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (e.g. painting, cataphoresis, etc.), it must not be damaged during transport;
• The transport and storage temperatures must match the values provided on the rating plate;
• If the device is not installed immediately after delivery, it must be stored away correctly in a dry and clean place;
• In humid facilities, use driers or heating to avoid condensation.
• At the end of its service life, the product must be disposed of in compliance with the legislation in force in the country where
this operation is performed.
8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described in this document;
• Failure to observe installation rules;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, the assembly of devices of other manufacturers, making changes to the device
and natural wear.
9.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
by the connection diameter
• Cl. ...
= Backflow seal strength
(A = 150 mbar - B = 50 mbar) in accordance with EN 161
• Gr. 2
= Mechanical strength of unit 2 in accordance with EN 161
• EN 161
= Product reference regulation
• P.max
= Maximum pressure at which product operation is guaranteed
• IP....
= Protection rating
• 230V....
= Power supply voltage, frequency (if Vac), followed by the electrical absorption
Example of electrical absorption indication: 83/16 VA indicates 83 VA at start, 16 VA at steady state
• (-20...+60) °C
= Temperature range within which product operation is guaranteed
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1802
= Lot issued in year 2018 in the 2
• 1065
= progressive job order number for the specified year
• 00001
= progressive number referring to the quantity of the lot
EVPF/NC - EVPR/NC
Mod: EVPF/NC DN 250
CI.B GR.2 EN 161
IP65 – 230 V/50 Hz 83/16 VA
year: 2018
week
nd
14
Madas Technical Manual - 1|1.2e - REV. 0 of 10
P. max: 360 bar
(-20...+60) °C
Lot: U1802
1065/00001
th
May 2018

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Evpr/nc

Tabla de contenido