time is automatically interrupted by the
activation of any safety system, and is
deactivated after a STOP command or
in case of power failure;
- Partial opening. Opening of the gate to
allow for foot traffic; activated by
connecting to terminals 2-3P and
adjusted with the AP-PARZ. trimmer.
With this function, the automatic closing
can vary in the following way:
1) Dip 12 set to ON: after a partial open-
ing, the time for automatic closing func-
tions independently of the adjustment of
the TCA trimmer and of the position of
Dip 1; it is set at 8 seconds.
2) Dip 12 set to OFF: after a partial
opening, the time for automatic closing
is adjustable only if Dip 1 is set to ON.
- Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from
the moment the doors begin to open
until they are completely closed
(including the time required for the
automatic closure). In case automatic
closure is not enabled, the lamp remains
lit only during movement (E-EX), see
p.16;
- Courtesy Light. A light that illuminates
the manoeuvring zone; after an opening
command, the light remains on for a
fixed time of 5 minutes and 30 seconds
(E-EX), see page 16;
-" Operator present" function: Gate
operates only when the pushbutton is
held down (the radio remote control
system is deactivated);
- Pre-flashing for 5 seconds, while the
door is opening and closing;
- Master function ; the panel assumes all
the command functions when two paired
motors are used (see page 30);
- Slave function ; this panel is exclusively
controlled by the "MASTER" (see page
30);
- Enabling functions of partial stop or re-
closure during opening, normally-closed
contact (2-CX), select one of the two
functions by setting dip (see selection of
functions);
- Type of command:
-open-close-reverse by button and
transmitter;
-open-stop-close-stop by button and
transmitter;
-open only by transmitter.
Adjustments
- Automatic closure time;
- Partial opening time.
Important! Disconnect the unit
from the main power lines before
carrying out any operation inside the
unit.
-5-