Important: Read complete instructions before beginning installation.
Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and fittings neces-
sary for whirlpool operation. An optional drain/overflow kit is available for installation on the bath.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift
the bath by the plumbing at any time; handle by the shell only.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the finish, do not
install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the warranty. Jacuzzi Whirlpool Bath's
responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims for damage to the
carrier. For definitions of warranty coverage and limitations, refer to the published warranty information packed with the product.
all bath units are factory tested for proper operation and watertight connections prior to shipping. NOTE: Prior to installation, the
bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling.
Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered, repaired, or avoided by following this inspec-
tion and testing procedure.
RECTANGULAR BATHS
L
SIDE VIEW
BATHS WITH INTEGRAL SKIRT

SPECIFICATIONS

(Rectangular) LH = Left Hand, RH = Right Hand
MODEL
DIMENSIONS
**
60"
(1524 mm) L
ESPREE 542
42"
(1067 mm) W
BACK MASSAGE
20"
( 508 mm) H
LH
ESPREE 6032
60"
(1524 mm) L
32"
( 813 mm) W
LH
22"
( 559 mm) H
*
ESPREE 6032
60"
(1524 mm) L
WITH INTEGRAL
32"
( 813 mm) W
SKIRT
22"
( 559 mm) H
LH & RH
ESPREE 6036
60"
(1524 mm) L
36"
( 914 mm) W
LH
20"
( 508 mm) H
ESPREE 6042
60"
(1524 mm) L
42"
(1067 mm) W
LH
20"
( 508 mm) H
*
ESPREE 6042
60"
(1524 mm) L
WITH INTEGRAL
42"
(1067 mm) W
SKIRT
20"
( 508 mm) H
LH & RH
ESPREE 7236
72"
(1829 mm) L
36"
( 914 mm) W
LH
20"
( 508 mm) H
ESPREE 7242
72"
(1829 mm) L
42"
(1067 mm) W
LH
20"
( 508 mm) H
*Add 1/4" (6.4 mm) to this dimension when roughing-in for 3-wall niche.
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6.4 mm).
FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeat
TM
: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
Motor/Pump: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
**120 VAC, 20 AMP, 60 Hz. *120 VAC, 20 AMP, 60 Hz.
Copyright © 2007 by Jacuzzi Whirlpool Bath
SPECIFICATIONS
(25.4 mm)
W
1"
H
END VIEW
A
B
DRAIN/OVERFLOW
DRAIN/OVERFLOW
DIMENSIONS
CUTOUT
16-7/8"
(429 mm) A
58" x 40"
(1473 mm x 1016 mm)
11-1/2"
(292 mm) B
18-1/16"
(459 mm) A
See
10-1/4"
(273 mm) B
Page 9
18-1/16"
(459 mm) A
NA
10-1/4"
(260 mm) B
16-7/8"
(429 mm) A
58" x 34"
(1473 mm x 863 mm)
15-7 /16"
(392 mm) B
16-7/8"
(429 mm) A
58" x 40"
11-1/4"
(286 mm) B
(1473 mm x 1016 mm)
16-7/8"
(429 mm) A
NA
10-13/16"
(275 mm) B
16-7/8"
(432 mm) A
70" X 34"
(1778 mm x 863 mm)
15-5/8"
(394 mm) B
16-7/8"
(432 mm) A
70" X 40"
(1778 mm x 1016 mm)
15-5/8"
(394 mm) B
L
(Motor)
SIDE VIEW
BATHS WITHOUT INTEGRAL SKIRT, 6036, 6042, 7236, & 7242
L
(Motor)
SIDE VIEW
BATHS WITHOUT INTEGRAL SKIRT, 542BM & 6032
AVERAGE
TOTAL WEIGHT/
OPERATING
PRODUCT
FLOOR LOADING
GALLONAGE
WEIGHT
927 lb
110 lb
60 Min U.S. gal
(421 kg)/
(227 liters)
(50 kg)
54 lb/ft
2
68 Max U.S. gal
(263 kg/m
)
2
(257 liters)
785 lb
50 Min U.S. gal
102 lb
(357 kg)/
(189 liters)
(46 kg)
59 lb/ft
58 Max U.S. gal
2
(288 kg/m
2
)
(220 liters)
785 lb
50 Min U.S. gal
108 lb
(357 kg)/
(189 liters)
(49 kg)
59 lb/ft
2
58 Max U.S. gal
(288 kg/m
)
(220 liters)
2
825 lb
50 Min U.S. gal
117 lb
(375 kg)/
(189 liters)
(53 kg)
55 lb/ft
2
61 Max U.S. gal
(268 kg/m
)
(231 liters)
2
927 lb
60 Min U.S. gal
110 lb
(421 kg)/
(227 liters)
(50 kg)
54 lb/ft
2
68 Max U.S. gal
(263 kg/m
)
(257 liters)
2
944 lb
60 Min U.S. gal
127 lb
(429 kg)/
(227 liters)
(57 kg)
55 lb/ft
2
68 Max U.S. gal
(268 kg/m
2
)
(257 liters)
978 lb
64 Min U.S. gal
120 lb
(445 kg)/
(242 liters)
(55 kg)
54 lb/ft
73 Max U.S. gal
2
(263 kg/m
2
)
(276 liters)
1112 lb
74 Min U.S. gal
120 lb
(505 kg)/
(280 liters)
(55 kg)
53 lb/ft
89 Max U.S. gal
2
(258 kg/m
2
)
(336 liters)

W
2"
(Motor)
(51 mm)
H
END VIEW
W
2"
(Motor)
(51 mm)
H
END VIEW
HEATER READY FOR
SKIRT &
FIELD INSTALLATION
MOUNTING
Not Avail-
Yes
able
(S750000 HEATER KIT)
Not
Yes
Available
(S750000 HEATER KIT)
Integral
Yes
(S750000 HEATER KIT)
Not
Yes
Available
(U395000 HEATER KIT,
or
S750000 HEATER KIT)
Not Avail-
Yes
able
(S750000 HEATER KIT)
Integral
Yes
(S750000 HEATER KIT)
Not
Yes
Available
(U395000 HEATER KIT,
or
S750000 HEATER KIT)
Not
Yes
Available
(U395000 HEATER KIT,
or
S750000 HEATER KIT)