- Insert wafers
with the number 1 into the chambers
- Insert the key and check whether the wafers with the number 1 fi t.
- Replace wafers that do not fi t with wafers with the right number.
NOTE
The wafers should be aligned fl ush with the locking cylinder. The
number of visible grooves indicates which wafer needs to be used.
This example shows a cylinder in which three wafers with number
1 have been installed. Two grooves are visible on each of the two
protruding wafers. This means that wafers with number 3 need to
be installed.
It is advisable to note down which numbers the matching wafers
have so that the other locking cylinders can be assembled in the
same manner.
- Repeat the steps for chambers
chambers are fi lled with the matching wafers.
- Insert spring
for the snap-in plate and then the snap-in plate
into chamber
.
NOTE
Chambers
and
remain empty.
- Mount O-ring
.
- Position locking cylinder as shown in the illustration and insert with
the aid of the key (catch must face upward).
Snap-in plate
engages.
,
and
,
and
until the fi rst six
.