Note
If frost-free storage is not possible:
2. Open the water volume regulation valve completely.
3. Stand the device upright and allow it to drain.
Illustration K
Care and service
Replacing the brushes
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Note
Always replace both brushes at the same time. The
brushes must be replaced when the gearbox housing
touches the ground while cleaning the surface without
exerting pressure on the device.
ATTENTION
Danger of burns
The gearbox can be very hot after use. Allow the device
to cool down before replacing the brushes.
1. Unscrew and remove the brush fasteners.
2. Pull out the worn brushes.
3. Fit the new brushes.
4. Fit and tighten the brush fasteners.
Illustration L
Pay attention to the assignment when fitting the
brush fasteners (left / right, as seen on the type
plate)!
Cleaning the water filter
Note
If the water flow is inadequate then the water filter in the
device must be cleaned.
1. Unscrew the plug connector at the water connec-
tion.
2. Pull out the water filter.
3. Clean the water filter under running water against
the normal flow direction.
Illustration M
4. Fit the water filter.
5. Screw on the plug connector.
Ensure that the sealing ring in the plug connector has
been inserted correctly.
Cleaning
ATTENTION
Improper cleaning
Damage to the device
Do not clean the device with a hose or high-pressure
water jet.
Do not use aggressive detergents.
Do not knock the brush on the ground.
1. Remove soiling, plant residue and sand/stone from
the brush.
2. If necessary, remove the brushes and clean them
under running water.
3. Clean the device with a moist cloth.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Device does not run or switches off during opera-
tion
14
No voltage supply
Check the voltage supply (plug connections of the
extension cable).
The fault current protection switch has triggered
Check the in-house fault current protection switch.
Consult a qualified electrician if the fault occurs fre-
quently.
The motor overload switch has triggered
Allow the device to cool down (at least 10 minutes).
The motor overload switch resets automatically and
the device is ready for operation again.
The power switch must not be pressed during
the cooling phase to avoid the device starting up
unexpectedly. Always wait for the specified
cooling time before restarting the device. In
case of a repeated shut-down, reduce the pres-
sure on the brushes while cleaning and hold the
device at a flatter angle.
Unsatisfactory cleaning results
Dirty brushes
Clean the air brushes.
Worn brushes
Replace the brushes.
Clogged water filter
Cleaning the water filter
Replace the water filter
Clogged water nozzles
Have the water nozzles replaced by an authorised
Customer Service department.
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Device performance data
Working voltage of the battery
Phase
Brush speed
Brush diameter
Dimensions and weights
Weight
Length x width x height
Subject to technical modifications.
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: Floor cleaner
Type: PCL 4
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
English
Warranty
V
~
1/min
mm
kg
mm
220-240
1
600-800
100
4,9
1281 x 3
07 x 350