Example Of Level 1 Programming; 10 7.3 Adding Or Removing Devices - Nice Ten TNKCE Instrucciones Y Advertencias Para El Instalador

Ocultar thumbs Ver también para Ten TNKCE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
7.2.5) Level 1 programming examples (ON-OFF functions)
This example shows the sequence of operations required to change the factory setting of the functions to activate the functions of "High
opening speed" (L2) and "Automatic Closure" (L3).
Table 18: Example of LEVEL 1 programming
1.
Press and hold [Set] for approx. 3s
2.
Release the key [Set] when led L1 starts to flash
3.
Press the key [▼] once to move the flashing led onto led L2
4.
Press [Set] once to change the status of the function associated with L2 (Opening speed) led L2
now emits long flashes
5.
Press the key [▼] once to move the flashing led onto led L3
6.
Press [Set] once to change the status of the function associated with L3 (Automatic closure) led L3
now emits long flashes
7.
Wait 10s to exit the programming mode automatically after the maximum time interval.
At the end of these operations leds L2 and L3 must remain lit to indicate that the functions "High opening speed" and "Automatic closure"
are enabled.
7.2.6) Example of Level 2 programming (adjustable parameters)
This example shows the sequence of operations required to change the factory setting of the parameters and set the functions of "Motor
Force" to high (input on L1 and level on L3) and increase the "Pause Time" to 60s (input on L3 and level on L3).
Table 19: Example of Level 2 programming
1.
Press and hold [Set] for approx. 3s
2.
Release the key [Set] when led L1 starts to flash
3.
Press and hold [Set] during steps 4 and 5
4.
Wait approx. 3s until led L2 lights up, indicating the current level of "Motor Force"
5.
Press the key [▼] once to move the illuminated led onto L3, indicating the new value of "Motor Force"
6.
Release [Set]
7.
Press [▼] twice to move the flashing led onto led L3
8.
Press and hold [Set] during steps 9 and 10
9.
Wait approx. 3s until led L2 lights up, indicating the current level of "Pause Time".
10.
Press the key [▼] once to move the illuminated led onto L3, indicating the new value of "Pause Time".
11.
Release [Set]
12.
Wait 10s to exit the programming mode automatically after the maximum time interval.
7.3) Adding or removing devices
Devices can be added or removed at any time on an automation
using TEN. In particular the inputs STOP and PHOTO can be con-
nected to various types of device as indicated in paragraphs "7.3.1
STOP Input" and "7.3.2 Photocells". Figure 33 shows the wiring dia-
gram for connection of the various devices.
18
33
Example
SET
3s
SET
L1
L2
SET
L2
L3
SET
L3
10s
Example
SET
3s
SET
L1
SET
L2
3s
L2
SET
L3
SET
L2
3s
L3
SET
10s

Publicidad