7.2.2) Level 1 programming (ON-OFF functions)
The factory settings of Level 1 functions are all set to "OFF" but can be changed at any time as described in Table 15. Take into account that
during the procedure there is a maximum time limit of 10 seconds between pressing one key and the next; if this limit is exceeded the pro-
cedure terminates automatically, memorising only the changes made up until that time.
Table 15: To modify the ON-OFF functions
1.
Press and hold [Set] for approx. 3s
2.
Release [Set] when led L1 starts flashing
3.
Press keys [▲] or [▼]to move the flashing led to the led associated with the function to be modified
4.
Press [Set] to change the status of the function (short flash = OFF; long flash = ON)
5.
Wait 10s to exit the programming mode automatically after the maximum time interval.
NOTE: points 3 and 4 can be repeated during the same programming phase to set other functions to ON or OFF
7.2.3) Level 2 functions (adjustable parameters)
Table 16: List of programmable functions: Level 2
Input leds
Parameter
L1
Motor FORCE
L2
SS function
L3
Pause Time
Note: "
" Represents factory settings
* if the motor speed is set to "high" on opening and closing and the motor force is set to "high", the deceleration phases are disabled (exclud-
ing deceleration in closure on approach to the mechanical stop).
All parameters can be adjusted as required without any contraindi-
cations, only the "Motor force" setting may require special attention:
• Use of high force values are not recommended to compensate for
the fact that the leaf has anomalous points of friction; excessive
force may impair the safety system and damage the leaf.
• If the "Motor force control" is used in support of the system for
impact force reduction, after each adjustment the force measure-
7.2.4) Level 2 programming (adjustable parameters)
By default the settable parameters are set as shown in Table 16 with: "
Take into account that during the procedure there is a maximum time limit of 10 seconds between pressing one key and the next; if this lim-
it is exceeded the procedure terminates automatically, memorising only the changes made up until that time.
Table 17: To change settable parameters
1.
Press and hold [Set] for approx. 3s
2.
Release the key [Set] when led L1 starts to flash
3.
Press keys [▲] or [▼] to move the flashing led to the "input led" associated with the parameter to
be modified
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3s after which the led associated with the current level of the parameter to be modified
will light up.
6.
Press keys [▲] or [▼] to move the led associated with the parameter value
7.
Release [Set]
8.
Wait 10s to exit the programming mode automatically after the maximum time interval.
Note: Points 3 to 7 can be repeated during the same programming phase to modify other parameters
Led (level)
Value
L1
Low
L2
Medium
L3
High *
L1
Open - Stop - Close -Open
L2
Open, Stop, Close, Stop
L3
Apartment block
L1
15 seconds
L2
30 seconds
L3
60 seconds
Description
Adjusts sensitivity of the motor force control to adapt it
to the type of door "High" is most suited to large size
heavy weight doors
Adjusts the sequence of commands associated with
the SS input or the 1st radio command (see tables 7
and 8).
Adjusts the pause time, i.e. time before automatic clo-
sure is effective only if automatic closure is enabled
ment procedure must be performed, as envisaged by standard EN
12445.
• Wear and atmospheric conditions influence movement of the gate;
force settings should be checked periodically
" but these can be changed at any time as described in Table 17.
GB
Example
SET
3s
SET
L1
or
SET
10s
Example
SET
3s
SET
L1
or
SET
or
SET
10s