4 Technical data

Right of technical changes reserved.
Power tool
Rated current / power
input
Rated frequency
Rated speed
Max. washer diameter
Dimensions (L x H x W)
without hood
Weight in accordance
with EPTA procedure
01/2003
Information about the power tool and applications
Drive spindle thread (arbor size)
Spindle length
Protection class as per EN / IEC
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise information (as perEN 60745‑1):
Typical A-weighted sound power level, DCG 125
Typical A-weighted emission sound pressure level,
DCG 125
Typical A-weighted sound power level, DAG 125
Typical A-weighted emission sound pressure level,
DAG 125
Uncertainty for the given sound level
Vibration information in accordance with EN 60745‑1
Triaxial vibration values (vibration vector sum) for the
DAG 125‑S / DAG 125‑SE
Surface grinding with the standard side handle, a
Surface grinding with the vibration-absorbing side
handle, a
h,AG
Surface grinding with the hoop handle, a
Uncertainty (K)
Triaxial vibration values (vibration vector sum) for the
DCG 125‑S
Surface grinding with the standard side handle, a
DCG 125‑S
Rated voltage 220 / 230
V: 6.4 A / 1,400 W
Rated voltage 110 V:
12.2 A / 1,200 W
50 / 60 Hz
11,000/min
Diameter 125 mm
304 mm x 103 mm x
82 mm
2.4 kg
h,AG
h,AG
h,AG
DAG 125‑S
Rated voltage 220 / 230
V: 5.0 A / 1,100 W
Rated voltage 110 V:
10.2 A / 1,050 W
50 / 60 Hz
11,000/min
Diameter 125 mm
289 mm x 103 mm x
82 mm
2.2 kg
M 14
22 mm
Protection class II (double insulated)
101 dB (A)
90 dB (A)
98 dB (A)
87 dB (A)
3 dB (A)
measured in accordance with EN 60745‑2‑3
5.8 m/s²
4.6 m/s²
5.9 m/s²
1.5 m/s²
measured in accordance with EN 60745‑2‑3
6.4 m/s²
DAG 125‑SE
Rated voltage 220 / 230
V: 5.0 A / 1,100 W
Rated voltage 110 V:
10.2 A / 1,050 W
50 / 60 Hz
2,800...11,000/min
Diameter 125 mm
289 mm x 103 mm x
82 mm
2.2 kg
23