3.4
INSTALLATION: Figure 8 illustrates installation of the Concrete Detent Anchor. Installation steps are as
follows:
IMPORTANT: When properly installed, the Anchor Socket will be permanently set in the concrete wall/
floor and cannot be removed.
Step 1.
Drill a 4 1/4 inch (10.8 cm) deep hole at the desired mounting location (Figure 7) with a Rotary
Hammer and industrial grade 7/8 inch (22 mm) Rotary Hammer Drill Bit.
WARNING: Before drilling holes, inspect the hole location to prevent drilling into power
transmission cables or other live utilities.
Step 2.
The mounting hole must be free of debris for the Anchor Socket to bond securely in the mounting
hole. Blow all debris out of the hole with a Blow-Out Bulb or Compressed Air; remove loose
particles with a Hole Brush; and then blow out the hole again to remove any remaining debris.
Step 3.
Inject Hilti HIT-150 MAX, Simpson SET Epoxy-Tie, or Fisher FIS-V adhesive into the mounting hole
to a depth of 1/3 to 1/2 full.
NOTe: Always follow the adhesive manufacturer's instructions when applying adhesive in the
mounting hole..
Step 4.
Slowly Thread the Anchor Socket into the mounting hole with the provided M6 Allen Wrench
until 1/16 inch (1.6 mm) of the socket remains above the concrete surface. Remove any excess
adhesive protruding from the hole and allow the adhesive to set and cure per the manufacturer's
recommendations.
Step 5.
Once the adhesive has had sufficient time to set and cure, press the Detent Button on the Detent
Pin and insert the Detent Pin in the Anchor Socket. Release the Detent Button and then pull on
the Detent Pin to ensure it is locked in the Anchor Socket.
Steps 1 - 3:
1
Drill 4
4
7
" (22 mm) Ø mounting hole.
8
Fill hole
with Hilti HIT-150 MAX, Simpson SET
Epoxy-Tie, or Fischer FIS-V Adhesive.
Step 4:
Figure 8 - Anchor Socket and Detent Pin Installation
" (10.8 cm) deep
1
to
1
full
3
2
Screw socket into
mounting hole until
1
16
thread remains
above top of concrete.
Detent Button :
1. Press Detent Button.
2. Insert Detent Pin in Socket.
3. Release Detent Button.
" (1.6 mm) of
7
Step 5: